Worked example
Example: 5 t/h from 11 bar(a) to 1.5 bar(a), 15 m/s, 80 mm line. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Condensate flow | 5,000.0 kg/h |
| Pressure before the trap (absolute) | 11.000 bar |
| Pressure in the return line (absolute) | 1.5000 bar |
| Allowed mixture velocity | 15.000 m/s |
| Inside diameter of the line to check | 80.000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flash fraction (steam per kg of condensate) | 14.111 % |
| Flash steam | 705.55 kg/h |
| Specific volume of the mixture | 0.16450 m³/kg |
| Volume flow of the mixture | 822.51 m³/h |
| Smallest inside diameter for the allowed velocity | 139.26 mm |
| Mixture velocity in the line checked | 45.454 m/s |
Open this example in the calculator and change any input.
Formula
\(x = \frac{h_{f1} - h_{f2}}{h_{g2} - h_{f2}}\)
\(v_m = x\, v_{g2} + (1 - x)\, v_{f2}\)
\(\dot V = \dot m\, v_m, \quad d_{min} = \sqrt{\frac{4 \dot V}{\pi u_{max}}}, \quad u = \frac{4 \dot V}{\pi d^2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m\) | Condensate flow | kg/s |
| \(p_1\) | Pressure before the trap (absolute) | Pa |
| \(p_2\) | Pressure in the return line (absolute) | Pa |
| \(u_{max}\) | Allowed mixture velocity | m/s |
| \(d\) | Inside diameter of the line to check | m |
| \(x\) | Flash fraction (steam per kg of condensate) | - |
| \(\dot m_{fs}\) | Flash steam | kg/s |
| \(v_m\) | Specific volume of the mixture | m³/kg |
| \(\dot V\) | Volume flow of the mixture | m³/s |
| \(d_{min}\) | Smallest inside diameter for the allowed velocity | m |
| \(u\) | Mixture velocity in the line checked | m/s |
| \(h_{f1}\) | Enthalpy of saturated water before the trap | J/kg |
| \(h_{f2}, h_{g2}\) | Saturated water and steam enthalpy in the return line | J/kg |
| \(v_{f2}, v_{g2}\) | Saturated water and steam specific volume in the return line | m³/kg |
Method and standards
Saturated condensate at the trap inlet pressure flashes at the lower return line pressure; the flash fraction follows from the energy balance with IAPWS-IF97 enthalpies. The homogeneous mixture volume then gives the velocity in a chosen pipe and the smallest pipe for an allowed velocity.
Where it is used
- Sizing trap discharge and condensate return lines.
- Checking existing return lines that hammer or are noisy.
- Deciding whether a flash vessel ahead of the return line is worthwhile.
Common mistakes
- Sizing the line for water only.
- Forgetting that condensate lifted after the trap raises the back pressure.
- Ignoring start-up loads, which can be several times the running load.
Assumptions and limits
- Condensate saturated at the trap inlet; steady flow.
- Homogeneous model; slip and slug flow are not modelled.
- Condensate taken as saturated at \(p_1\); subcooled condensate (traps that back up) flashes less, so the result is on the safe side.
- One return line pressure: the pressure drop along the line, and the extra flash it causes, are not modelled.
- A warning appears when the velocity in the line checked exceeds the allowed velocity.
References
- IAPWS-IF97 saturation properties
- Homogeneous two-phase flow model
Questions and answers
Why is a condensate line sized for steam, not water?
Part of the condensate flashes when it leaves the trap. 5 t/h from 11 bar(a) into a 1.5 bar(a) line flashes 14 %, and the mixture takes about 0.16 m³/kg, over 150 times the volume of saturated water in the return line.
What size does that need?
At 15 m/s the line must be at least 139 mm bore; an 80 mm line would carry the mixture at about 45 m/s, with noise and erosion.
What is the homogeneous model?
Steam and water are taken to move together at one velocity, so the mixture behaves as one fluid with the average specific volume. It is the usual first estimate.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.