Condensate Return Line Sizing with Flash Steam

Flash steam fraction, mixture volume and velocity in a condensate return line after the steam trap, and the line size for an allowed velocity, by the homogeneous model.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Flash vessel and condensate

Inputs

Examples: 5 t/h from 11 bar(a) to 1.5 bar(a), 15 m/s, 80 mm line2 t/h from 4 bar(a) to atmosphere, 12 m/s, 50 mm line20 t/h from 21 bar(a) to 3 bar(a), 20 m/s, 150 mm line

The condensate is taken as saturated water at this pressure.
Your design limit for the steam–water mixture in the return line.

Results

Homogeneous model: steam and water move at one velocity. Real lines slip and can slug; allow for lift after the trap and for start-up loads.

The velocity in the line checked (31.8 m/s) exceeds the allowed 20.0 m/s: use at least the smallest inside diameter shown.

Flash fraction (steam per kg of condensate)16.572%
Flash steam3,314.5kg/h
Specific volume of the mixture0.10129m³/kg
Volume flow of the mixture2,025.8m³/h
Smallest inside diameter for the allowed velocity189.27mm
Mixture velocity in the line checked31.843m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 5 t/h from 11 bar(a) to 1.5 bar(a), 15 m/s, 80 mm line. The inputs, in the units selected above:

InputValue
Condensate flow5,000.0 kg/h
Pressure before the trap (absolute)11.000 bar
Pressure in the return line (absolute)1.5000 bar
Allowed mixture velocity15.000 m/s
Inside diameter of the line to check80.000 mm

Applying the formula below gives:

ResultValue
Flash fraction (steam per kg of condensate)14.111 %
Flash steam705.55 kg/h
Specific volume of the mixture0.16450 m³/kg
Volume flow of the mixture822.51 m³/h
Smallest inside diameter for the allowed velocity139.26 mm
Mixture velocity in the line checked45.454 m/s

Open this example in the calculator and change any input.

Formula

\(x = \frac{h_{f1} - h_{f2}}{h_{g2} - h_{f2}}\)

\(v_m = x\, v_{g2} + (1 - x)\, v_{f2}\)

\(\dot V = \dot m\, v_m, \quad d_{min} = \sqrt{\frac{4 \dot V}{\pi u_{max}}}, \quad u = \frac{4 \dot V}{\pi d^2}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Condensate flow kg/s
\(p_1\) Pressure before the trap (absolute) Pa
\(p_2\) Pressure in the return line (absolute) Pa
\(u_{max}\) Allowed mixture velocity m/s
\(d\) Inside diameter of the line to check m
\(x\) Flash fraction (steam per kg of condensate) -
\(\dot m_{fs}\) Flash steam kg/s
\(v_m\) Specific volume of the mixture m³/kg
\(\dot V\) Volume flow of the mixture m³/s
\(d_{min}\) Smallest inside diameter for the allowed velocity m
\(u\) Mixture velocity in the line checked m/s
\(h_{f1}\) Enthalpy of saturated water before the trap J/kg
\(h_{f2}, h_{g2}\) Saturated water and steam enthalpy in the return line J/kg
\(v_{f2}, v_{g2}\) Saturated water and steam specific volume in the return line m³/kg

Method and standards

Saturated condensate at the trap inlet pressure flashes at the lower return line pressure; the flash fraction follows from the energy balance with IAPWS-IF97 enthalpies. The homogeneous mixture volume then gives the velocity in a chosen pipe and the smallest pipe for an allowed velocity.

Where it is used

  • Sizing trap discharge and condensate return lines.
  • Checking existing return lines that hammer or are noisy.
  • Deciding whether a flash vessel ahead of the return line is worthwhile.

Common mistakes

  • Sizing the line for water only.
  • Forgetting that condensate lifted after the trap raises the back pressure.
  • Ignoring start-up loads, which can be several times the running load.

Assumptions and limits

  • Condensate saturated at the trap inlet; steady flow.
  • Homogeneous model; slip and slug flow are not modelled.
  • Condensate taken as saturated at \(p_1\); subcooled condensate (traps that back up) flashes less, so the result is on the safe side.
  • One return line pressure: the pressure drop along the line, and the extra flash it causes, are not modelled.
  • A warning appears when the velocity in the line checked exceeds the allowed velocity.

References

  • IAPWS-IF97 saturation properties
  • Homogeneous two-phase flow model

Questions and answers

Why is a condensate line sized for steam, not water?

Part of the condensate flashes when it leaves the trap. 5 t/h from 11 bar(a) into a 1.5 bar(a) line flashes 14 %, and the mixture takes about 0.16 m³/kg, over 150 times the volume of saturated water in the return line.

What size does that need?

At 15 m/s the line must be at least 139 mm bore; an 80 mm line would carry the mixture at about 45 m/s, with noise and erosion.

What is the homogeneous model?

Steam and water are taken to move together at one velocity, so the mixture behaves as one fluid with the average specific volume. It is the usual first estimate.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.