Material Balance of the Tandem (Hugot)

Brix, sucrose and purity of absolute juice, first- and second-mill juice and final bagasse for a tandem with compound imbibition, after Hugot pp. 299–302.

Sugar mill and cogeneration

Inputs

Examples: Hugot exampleRicher cane

Results

Hugot's example (f 0.15, w 0.36, B₁ 20.73, p₁ 89, e 96 %) gives about 1.93 % sucrose in bagasse and second-mill juice of brix 8.7 and purity 84.

Brix of absolute juice20.747%
Sucrose per unit cane15.416%
Sucrose in first-mill juice per unit cane11.382%
Sucrose in final bagasse per unit cane0.69373%
Sucrose % final bagasse2.4281%
Second-mill juice per unit cane44.605%
Brix of second-mill juice8.8207%
Sucrose % second-mill juice7.4883%
Purity of second-mill juice84.894%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example. The inputs, in the units selected above:

InputValue
Fibre per unit cane15.000 %
Imbibition water per unit cane36.000 %
Brix of primary (first-mill) juice20.730 %
Purity of first-mill juice89.000 %
Extraction96.000 %
Purity of residual juice in the final bagasse50.000 %
Fibre in first-mill bagasse33.000 %
Fibre in final bagasse50.000 %
Brix ratio absolute / primary juice0.96500 -
Purity ratio absolute / primary juice0.96000 -

Applying the formula below gives:

ResultValue
Brix of absolute juice20.004 %
Sucrose per unit cane14.528 %
Sucrose in first-mill juice per unit cane10.063 %
Sucrose in final bagasse per unit cane0.58112 %
Sucrose % final bagasse1.9371 %
Second-mill juice per unit cane51.455 %
Brix of second-mill juice8.8122 %
Sucrose % second-mill juice7.5473 %
Purity of second-mill juice85.646 %

Open this example in the calculator and change any input.

Formula

\(B_0 = k_B B_1, \quad s_0 = (1 - f)B_0\,k_p p_1, \quad s_1 = (1 - b_1)B_1 p_1, \quad s_n = s_0(1 - e)\)

\(j_2 = 1 + w - b_n - j_1, \quad B_2 = \frac{M_0 - M_1 - s_n/p_n}{j_2}, \quad p_2 = \frac{s_0 - s_1 - s_n}{M_0 - M_1 - s_n/p_n}\)

Variables

Symbol Meaning SI unit
\(f\) Fibre per unit cane -
\(w\) Imbibition water per unit cane -
\(B_1\) Brix of primary (first-mill) juice -
\(p_1\) Purity of first-mill juice -
\(e\) Extraction -
\(p_n\) Purity of residual juice in the final bagasse -
\(F_1\) Fibre in first-mill bagasse -
\(F_n\) Fibre in final bagasse -
\(k_B\) Brix ratio absolute / primary juice -
\(k_p\) Purity ratio absolute / primary juice -
\(B_0\) Brix of absolute juice -
\(s_0\) Sucrose per unit cane -
\(s_1\) Sucrose in first-mill juice per unit cane -
\(s_n\) Sucrose in final bagasse per unit cane -
\(\sigma\) Sucrose % final bagasse -
\(j_2\) Second-mill juice per unit cane -
\(B_2\) Brix of second-mill juice -
\(S_2\) Sucrose % second-mill juice -
\(p_2\) Purity of second-mill juice -

Method and standards

Hugot's step-by-step balance of soluble matter and sucrose.

Where it is used

  • Checking mill juice analyses.
  • Teaching and auditing milling balances.

Common mistakes

  • Mixing pol and sucrose.
  • Using fibre % cane for bagasse fibre.

Assumptions and limits

  • Compound imbibition; only mills 1 and 2 send juice to process.
  • Sucrose and purity are apparent values (pol), as in factory control. The defaults for k_B and k_p are typical ratios, not from a cited source: use your own.
  • A second-mill juice with negative sucrose or purity above 100 % is rejected.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 19
  • material balance of the tandem
  • pp. 299–303

Questions and answers

Why is absolute juice brix below primary juice brix?

The first expressed juice is richer than the average juice in cane; Hugot takes B₀ = 0.965 B₁.

How is sucrose in bagasse found?

From the extraction: what is not extracted stays in the final bagasse.

Why does second-mill juice have lower purity?

Later pressings expel juice from inner cells, which is poorer, diluted by returned imbibition juice.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.