Mill Power: Simplified Formula and Torque Number

Mill power from load, speed and diameter with a coefficient from Hugot Table 14.8 (P = k F n D), the Murry torque number, and power per tonne fibre per hour.

Sugar mill and cogenerationElectric motor

Inputs

Examples: Hugot final mill exampleFirst mill

Hugot Table 14.8 (kW): normal running about 0.20 first mill, 0.17 second, 0.15 third and later; peak values about a fifth higher.

Results

Hugot's example of a final mill 813 × 1676 mm at 5 rpm and 340 t load absorbs about 200 kW.

Mill power at the rollers200.40kW
Murry torque number G/(F D)0.14119
Power per tonne fibre per hour13.821kWh/t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot final mill example. The inputs, in the units selected above:

InputValue
Coefficient k (kW per tonne-force, rpm and metre)0.14500 -
Total hydraulic load340.00 tf
Roller speed5.0000 rpm
Roller diameter0.81300 m
Crushing rate100.00 t/h
Fibre % cane14.500 %

Applying the formula below gives:

ResultValue
Mill power at the rollers200.40 kW
Murry torque number G/(F D)0.14119
Power per tonne fibre per hour13.821 kWh/t

Open this example in the calculator and change any input.

Formula

\(P = k\,F\,n\,D \;[\mathrm{kW};\ F\ \mathrm{t};\ n\ \mathrm{rpm};\ D\ \mathrm{m}], \quad N_M = \frac{G}{F D} = \frac{P}{2\pi n F D}\)

Variables

Symbol Meaning SI unit
\(k\) Coefficient k (kW per tonne-force, rpm and metre) -
\(F\) Total hydraulic load N
\(n\) Roller speed 1/s
\(D\) Roller diameter m
\(A\) Crushing rate kg/s
\(f\) Fibre % cane -
\(P\) Mill power at the rollers W
\(N_M\) Murry torque number G/(F D) -
\(P/(A f)\) Power per tonne fibre per hour J/kg

Method and standards

Hugot's simplified mill power and Murry's torque number.

Where it is used

  • Quick sizing of mill drives.
  • Comparing mill loads.

Common mistakes

  • Using the horsepower k with kW.
  • Load in kN in the tonne form.

Assumptions and limits

  • Hugot's coefficients for 3-roller mills.
  • With P = k F n D the Murry torque number reduces to N_M = 60k/(2πg) ≈ 0.974 k (k in kW per tonne-force, rpm and metre): it restates k in dimensionless form rather than adding information.
  • The default k = 0.145 reproduces Hugot's final-mill example (about 200 kW); normal running values in his table are about 0.15–0.20.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 14
  • eqns 14.9 and 14.11–14.12 and Table 14.8
  • pp. 234–237

Questions and answers

Why is power proportional to F n D?

Torque is roughly proportional to the load times the roller radius, and power is torque times speed.

What is the Murry number?

Torque divided by load times diameter; a dimensionless measure that compares mills of any size.

Which k?

Hugot's Table 14.8 gives k by mill position, preparation and feeding; the first mill takes the most.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.