Worked example
Example: Hugot example: 813 mm, F 340 t, r 1.3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Total hydraulic load on the top roller | 340.00 tf |
| Roller speed | 5.0000 rpm |
| Roller diameter | 0.81300 m |
| Roller length | 1.6760 m |
| Re-absorption factor | 1.3000 - |
| Working delivery opening | 13.330 mm |
| Compression coefficient | Later mills (0.40) |
| Journal and trashplate friction coefficient | 0.075000 - |
| Efficiency of the gearing | 78.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Re-absorption function (6r − 5)/(√r(1 + √(r − 1))) | 1.5867 |
| Compression power | 82.612 kW |
| Journal and trashplate friction | 76.240 kW |
| Scrapers and intermediate carrier | 20.044 kW |
| Power at the rollers | 178.90 kW |
| Power at the prime mover | 229.35 kW |
Open this example in the calculator and change any input.
Formula
\(P = nD\left\{F\left[k_1 f(r)\sqrt{e_A/D} + k_2\right] + 4L\right\} \;[\mathrm{metric\ hp}], \quad f(r) = \frac{6r - 5}{\sqrt r\,(1 + \sqrt{r - 1})}\)
\(P_{drive} = P/\rho\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(F\) | Total hydraulic load on the top roller | N |
| \(n\) | Roller speed | 1/s |
| \(D\) | Roller diameter | m |
| \(L\) | Roller length | m |
| \(r\) | Re-absorption factor | - |
| \(e_A\) | Working delivery opening | m |
| \(k_1\) | Compression coefficient | - |
| \(k_2\) | Journal and trashplate friction coefficient | - |
| \(\rho\) | Efficiency of the gearing | - |
| \(f(r)\) | Re-absorption function (6r − 5)/(√r(1 + √(r − 1))) | - |
| \(P_1\) | Compression power | W |
| \(P_2 + P_3\) | Journal and trashplate friction | W |
| \(P_4 + P_5\) | Scrapers and intermediate carrier | W |
| \(P\) | Power at the rollers | W |
| \(P/\rho\) | Power at the prime mover | W |
Method and standards
Hugot's analysis of mill power by components.
Where it is used
- Sizing mill drives.
- Understanding where mill power goes.
Common mistakes
- Using total load in kN in the hp form.
- Leaving out gearing losses.
Assumptions and limits
- Hugot's coefficients for normal 3-roller mills. In the compression term ε = e_A/D (Hugot's example: 13.3 mm on an 813 mm roller, ε = 0.0164).
- Notes flag k₂ outside Hugot's Table 14.5 range (0.046–0.107) and unusually high re-absorption factors.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 14
- eqns 14.1–14.7 and Tables 14.5–14.6
- pp. 227–234
Questions and answers
Where does most of the power go?
Compressing the blanket and friction at the journals and trashplate; scrapers and the carrier take a few percent.
Why does re-absorption appear?
The more the blanket swells and re-absorbs, the harder the mill must squeeze; f(r) carries that effect.
Which gearing efficiency?
Hugot's product of pinions, gear pairs and reducer comes to about 0.78–0.79.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.