FireCADCalc

Mill Power by Components (Hugot)

Power of a 3-roller mill by Hugot eqns 14.1–14.7: compression, journal and trashplate friction, scrapers and carrier, from load, speed, size and opening.

Sugar mill and cogenerationSteam turbineElectric motor

Inputs

Examples: Hugot example: 813 mm, F 340 t, r 1.3First mill after knives and shredder

Hugot Table 14.5: 0.046 minimum, 0.075 mean, 0.107 maximum.
Hugot: about 0.78–0.79 for open pinions, gears and a reducer.

Results

Hugot's formulae give metric horsepower with F in tonnes, n in rpm and D, L in metres; converted to kW here. Hugot's example (F 340 t, r 1.3, n 5, D 0.813 m, ε = e_A/D = 0.0164, i.e. e_A 13.3 mm) gives about 111 hp of compression.

Re-absorption function (6r − 5)/(√r(1 + √(r − 1)))1.7602
Compression power231.22kW
Journal and trashplate friction119.19kW
Scrapers and intermediate carrier30.145kW
Power at the rollers380.55kW
Power at the prime mover475.69kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example: 813 mm, F 340 t, r 1.3. The inputs, in the units selected above:

InputValue
Total hydraulic load on the top roller340.00 tf
Roller speed5.0000 rpm
Roller diameter0.81300 m
Roller length1.6760 m
Re-absorption factor1.3000 -
Working delivery opening13.330 mm
Compression coefficientLater mills (0.40)
Journal and trashplate friction coefficient0.075000 -
Efficiency of the gearing78.000 %

Applying the formula below gives:

ResultValue
Re-absorption function (6r − 5)/(√r(1 + √(r − 1)))1.5867
Compression power82.612 kW
Journal and trashplate friction76.240 kW
Scrapers and intermediate carrier20.044 kW
Power at the rollers178.90 kW
Power at the prime mover229.35 kW

Open this example in the calculator and change any input.

Formula

\(P = nD\left\{F\left[k_1 f(r)\sqrt{e_A/D} + k_2\right] + 4L\right\} \;[\mathrm{metric\ hp}], \quad f(r) = \frac{6r - 5}{\sqrt r\,(1 + \sqrt{r - 1})}\)

\(P_{drive} = P/\rho\)

Variables

Symbol Meaning SI unit
\(F\) Total hydraulic load on the top roller N
\(n\) Roller speed 1/s
\(D\) Roller diameter m
\(L\) Roller length m
\(r\) Re-absorption factor -
\(e_A\) Working delivery opening m
\(k_1\) Compression coefficient -
\(k_2\) Journal and trashplate friction coefficient -
\(\rho\) Efficiency of the gearing -
\(f(r)\) Re-absorption function (6r − 5)/(√r(1 + √(r − 1))) -
\(P_1\) Compression power W
\(P_2 + P_3\) Journal and trashplate friction W
\(P_4 + P_5\) Scrapers and intermediate carrier W
\(P\) Power at the rollers W
\(P/\rho\) Power at the prime mover W

Method and standards

Hugot's analysis of mill power by components.

Where it is used

  • Sizing mill drives.
  • Understanding where mill power goes.

Common mistakes

  • Using total load in kN in the hp form.
  • Leaving out gearing losses.

Assumptions and limits

  • Hugot's coefficients for normal 3-roller mills. In the compression term ε = e_A/D (Hugot's example: 13.3 mm on an 813 mm roller, ε = 0.0164).
  • Notes flag k₂ outside Hugot's Table 14.5 range (0.046–0.107) and unusually high re-absorption factors.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 14
  • eqns 14.1–14.7 and Tables 14.5–14.6
  • pp. 227–234

Questions and answers

Where does most of the power go?

Compressing the blanket and friction at the journals and trashplate; scrapers and the carrier take a few percent.

Why does re-absorption appear?

The more the blanket swells and re-absorbs, the harder the mill must squeeze; f(r) carries that effect.

Which gearing efficiency?

Hugot's product of pinions, gear pairs and reducer comes to about 0.78–0.79.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.