FireCADCalc

Maximal Imbibition a Final Mill Can Take (Hugot)

Highest imbibition on fibre a final mill takes without choking from water temperature, specific pressure, speed and specific fibre loading (Hugot eqn 19.21).

Sugar mill and cogeneration

Inputs

Examples: Hugot exampleHot water, high pressure

Results

Russell: no more than about 3.6 times the fibre at one mill; split heavier imbibition over two mills.

The regression comes from one set of mills; outside their conditions treat it as a rough guide.

Specific fibre loading17.689kg/m³
Maximal imbibition on fibre111.33%
Maximal imbibition water40.356t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hugot example. The inputs, in the units selected above:

InputValue
Crushing rate130.00 t/h
Fibre % cane12.500 %
Peripheral speed of the final mill12.500 m/min
Roller diameter0.81200 m
Roller length1.6760 m
Imbibition water temperature60.000 °C
Specific hydraulic pressure of the final mill25.000 t/dm²

Applying the formula below gives:

ResultValue
Specific fibre loading15.921 kg/m³
Maximal imbibition on fibre147.38 %
Maximal imbibition water23.949 t/h

Open this example in the calculator and change any input.

Formula

\(\lambda_M = 554 - 0.9\,t - 5\,p + 20\,v - 30\,\tau \;[\%\ \text{on fibre};\ t\ ^\circ\mathrm{C};\ p\ \mathrm{t/dm^2};\ v\ \mathrm{m/min};\ \tau\ \mathrm{kg/m^3}]\)

\(\tau = \frac{A f}{v\,D\,L}\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(f\) Fibre % cane -
\(v\) Peripheral speed of the final mill m/s
\(D\) Roller diameter m
\(L\) Roller length m
\(t\) Imbibition water temperature K
\(p\) Specific hydraulic pressure of the final mill Pa
\(\tau\) Specific fibre loading kg/m³
\(\lambda_M\) Maximal imbibition on fibre -
\(W_M\) Maximal imbibition water kg/s

Method and standards

Hugot eqn 19.21 (Handbook of Cane Sugar Engineering, 3rd ed., pp. 310–311), which Hugot built from two results of Haines and Hughes's regression for the final mill at Puunene, Hawaii. Hugot gives no range of validity; his worked example is a 812 × 1676 mm mill at 130 t cane/h, 12.5 % fibre, 25 t/dm², 12.5 m/min and 60 °C, giving 145 % imbibition on fibre.

Where it is used

  • Setting imbibition rates.
  • Diagnosing final-mill choking.

Common mistakes

  • Using pressure in kg/cm² instead of t/dm².
  • Applying it to diffusers.

Assumptions and limits

  • Regression from one set of mills; use as a guide. Their range of pressures, speeds and temperatures is not stated with the formula, so results far from Hugot's example (25 t/dm², 12.5 m/min, 60 °C) are extrapolations.
  • A note compares λ_M with Russell's limit of about 3.6 times the fibre.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 19
  • eqn 19.21 (after Haines and Hughes)
  • pp. 310–311

Questions and answers

What limits imbibition?

Usually the final mill choking, not evaporator capacity.

How can the limit be raised?

Colder water, lower hydraulic pressure, faster rollers or a lower crush rate, as the formula shows.

Hugot's example?

An 812 × 1676 mm final mill at 130 t/h, 12.5 % fibre, 25 t/dm², 12.5 m/min and 60 °C water takes about 145 % on fibre.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.