Worked example
Example: Hugot example. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 130.00 t/h |
| Fibre % cane | 12.500 % |
| Peripheral speed of the final mill | 12.500 m/min |
| Roller diameter | 0.81200 m |
| Roller length | 1.6760 m |
| Imbibition water temperature | 60.000 °C |
| Specific hydraulic pressure of the final mill | 25.000 t/dm² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Specific fibre loading | 15.921 kg/m³ |
| Maximal imbibition on fibre | 147.38 % |
| Maximal imbibition water | 23.949 t/h |
Open this example in the calculator and change any input.
Formula
\(\lambda_M = 554 - 0.9\,t - 5\,p + 20\,v - 30\,\tau \;[\%\ \text{on fibre};\ t\ ^\circ\mathrm{C};\ p\ \mathrm{t/dm^2};\ v\ \mathrm{m/min};\ \tau\ \mathrm{kg/m^3}]\)
\(\tau = \frac{A f}{v\,D\,L}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(f\) | Fibre % cane | - |
| \(v\) | Peripheral speed of the final mill | m/s |
| \(D\) | Roller diameter | m |
| \(L\) | Roller length | m |
| \(t\) | Imbibition water temperature | K |
| \(p\) | Specific hydraulic pressure of the final mill | Pa |
| \(\tau\) | Specific fibre loading | kg/m³ |
| \(\lambda_M\) | Maximal imbibition on fibre | - |
| \(W_M\) | Maximal imbibition water | kg/s |
Method and standards
Hugot eqn 19.21 (Handbook of Cane Sugar Engineering, 3rd ed., pp. 310–311), which Hugot built from two results of Haines and Hughes's regression for the final mill at Puunene, Hawaii. Hugot gives no range of validity; his worked example is a 812 × 1676 mm mill at 130 t cane/h, 12.5 % fibre, 25 t/dm², 12.5 m/min and 60 °C, giving 145 % imbibition on fibre.
Where it is used
- Setting imbibition rates.
- Diagnosing final-mill choking.
Common mistakes
- Using pressure in kg/cm² instead of t/dm².
- Applying it to diffusers.
Assumptions and limits
- Regression from one set of mills; use as a guide. Their range of pressures, speeds and temperatures is not stated with the formula, so results far from Hugot's example (25 t/dm², 12.5 m/min, 60 °C) are extrapolations.
- A note compares λ_M with Russell's limit of about 3.6 times the fibre.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 19
- eqn 19.21 (after Haines and Hughes)
- pp. 310–311
Questions and answers
What limits imbibition?
Usually the final mill choking, not evaporator capacity.
How can the limit be raised?
Colder water, lower hydraulic pressure, faster rollers or a lower crush rate, as the formula shows.
Hugot's example?
An 812 × 1676 mm final mill at 130 t/h, 12.5 % fibre, 25 t/dm², 12.5 m/min and 60 °C water takes about 145 % on fibre.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.