FireCADCalc

Best Split of Water in Double Simple Imbibition

Share of imbibition water to apply at the last mill and at the one before for the best extraction, Hugot eqn 19.20, from imbibition on fibre and bagasse fibres.

Sugar mill and cogeneration

Inputs

Examples: 250 TCH, lambda about 2Low imbibition

Results

The optimum is flat: if the last mill chokes, a nearly equal split costs little extraction.

Imbibition per unit fibre0.80000
Share of the water at the last mill73.271%
Water at the last mill13.189t/h
Water at the penultimate mill4.8112t/h
Imbibition below which all water goes to the last mill0.37234

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 250 TCH, lambda about 2. The inputs, in the units selected above:

InputValue
Crushing rate250.00 t/h
Fibre per unit cane14.500 %
Imbibition water per unit cane30.000 %
Fibre in bagasse from the antepenultimate mill44.000 %
Fibre in bagasse from the penultimate mill47.000 %

Applying the formula below gives:

ResultValue
Imbibition per unit fibre2.0690
Share of the water at the last mill53.506 %
Water at the last mill40.129 t/h
Water at the penultimate mill34.871 t/h
Imbibition below which all water goes to the last mill0.14507

Open this example in the calculator and change any input.

Formula

\(\lambda = \frac{w}{f}, \quad \lambda_{lim} = \frac{1}{m_1} - \frac{1}{m_2}, \quad x = \min\left(1, \frac12 + \frac{\lambda_{lim}}{2\lambda}\right), \quad W_l = x\,A w, \quad W_p = (1 - x)A w\)

Variables

Symbol Meaning SI unit
\(A\) Crushing rate kg/s
\(f\) Fibre per unit cane -
\(w\) Imbibition water per unit cane -
\(m_1\) Fibre in bagasse from the antepenultimate mill -
\(m_2\) Fibre in bagasse from the penultimate mill -
\(\lambda\) Imbibition per unit fibre -
\(x\) Share of the water at the last mill -
\(W_l\) Water at the last mill kg/s
\(W_p\) Water at the penultimate mill kg/s
\(\lambda_{lim}\) Imbibition below which all water goes to the last mill -

Method and standards

Hugot's maximum of the extraction of the last two mills.

Where it is used

  • Setting imbibition distribution.
  • Checking a two-point simple imbibition.

Common mistakes

  • Using % on cane for λ.
  • Swapping m₁ and m₂.

Assumptions and limits

  • Double simple imbibition at the last two mills.
  • When λ is at or below λ_lim the share is capped at 100 % (all water at the last mill) and a note says so.

References

  • Hugot
  • Handbook of Cane Sugar Engineering
  • 3rd ed. (Elsevier, 1986)
  • ch. 19
  • eqn 19.20
  • pp. 304–307

Questions and answers

Why slightly more than half at the last mill?

Its bagasse holds less juice; more water there balances the dilution of the two mills.

When does all water go to the last mill?

When λ falls to 1/m₁ − 1/m₂, generally below 0.3: rare in practice.

Does β change the answer?

Hugot shows it acts symmetrically and hardly moves the optimum.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.