Worked example
Example: 250 TCH, lambda about 2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Crushing rate | 250.00 t/h |
| Fibre per unit cane | 14.500 % |
| Imbibition water per unit cane | 30.000 % |
| Fibre in bagasse from the antepenultimate mill | 44.000 % |
| Fibre in bagasse from the penultimate mill | 47.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Imbibition per unit fibre | 2.0690 |
| Share of the water at the last mill | 53.506 % |
| Water at the last mill | 40.129 t/h |
| Water at the penultimate mill | 34.871 t/h |
| Imbibition below which all water goes to the last mill | 0.14507 |
Open this example in the calculator and change any input.
Formula
\(\lambda = \frac{w}{f}, \quad \lambda_{lim} = \frac{1}{m_1} - \frac{1}{m_2}, \quad x = \min\left(1, \frac12 + \frac{\lambda_{lim}}{2\lambda}\right), \quad W_l = x\,A w, \quad W_p = (1 - x)A w\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A\) | Crushing rate | kg/s |
| \(f\) | Fibre per unit cane | - |
| \(w\) | Imbibition water per unit cane | - |
| \(m_1\) | Fibre in bagasse from the antepenultimate mill | - |
| \(m_2\) | Fibre in bagasse from the penultimate mill | - |
| \(\lambda\) | Imbibition per unit fibre | - |
| \(x\) | Share of the water at the last mill | - |
| \(W_l\) | Water at the last mill | kg/s |
| \(W_p\) | Water at the penultimate mill | kg/s |
| \(\lambda_{lim}\) | Imbibition below which all water goes to the last mill | - |
Method and standards
Hugot's maximum of the extraction of the last two mills.
Where it is used
- Setting imbibition distribution.
- Checking a two-point simple imbibition.
Common mistakes
- Using % on cane for λ.
- Swapping m₁ and m₂.
Assumptions and limits
- Double simple imbibition at the last two mills.
- When λ is at or below λ_lim the share is capped at 100 % (all water at the last mill) and a note says so.
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 19
- eqn 19.20
- pp. 304–307
Questions and answers
Why slightly more than half at the last mill?
Its bagasse holds less juice; more water there balances the dilution of the two mills.
When does all water go to the last mill?
When λ falls to 1/m₁ − 1/m₂, generally below 0.3: rare in practice.
Does β change the answer?
Hugot shows it acts symmetrically and hardly moves the optimum.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.