Worked example
Example: Daily balance. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Cane crushed | 5,000.0 t |
| Added (imbibition) water | 1,500.0 t |
| Gross mixed juice | 5,100.0 t |
| Drit correction % mixed juice | 1.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Drit | 51.000 t |
| Net mixed juice | 5,049.0 t |
| Net mixed juice % cane | 100.98 % |
| Added water % cane | 30.000 % |
| Bagasse % cane (cane + water − gross juice) | 28.000 % |
Open this example in the calculator and change any input.
Formula
\(D = MJ_g k_d, \quad MJ_n = MJ_g - D, \quad B = \frac{C + W_a - MJ_g}{C}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C\) | Cane crushed | kg |
| \(W_a\) | Added (imbibition) water | kg |
| \(MJ_g\) | Gross mixed juice | kg |
| \(k_d\) | Drit correction % mixed juice | - |
| \(D\) | Drit | kg |
| \(MJ_n\) | Net mixed juice | kg |
| \(MJ\) | Net mixed juice % cane | - |
| \(AW\) | Added water % cane | - |
| \(B\) | Bagasse % cane (cane + water − gross juice) | - |
Method and standards
Mass balance.
Where it is used
- Daily manufacturing report.
Common mistakes
- Net juice used in the bagasse balance.
Assumptions and limits
- Same period for all weights.
- The balance is C + W_a = MJ_g + B, so with net juice it reads C + W_a = MJ_n + B + D: the drit is neither bagasse nor net juice. Some DMR conventions treat drit differently.
- A note appears when bagasse % cane is outside about 25–35 %.
References
- Sugar factory chemical control (daily manufacturing report) definitions
- as compiled in SugarProcessTech
- Formulas for calculating sugar industry DMR
Questions and answers
What is drit?
Suspended soil and fibre in mixed juice, deducted from its weight.
Why bagasse by difference?
Bagasse is rarely weighed; cane and water in equal juice and bagasse out.
Gross or net juice in the balance?
The balance uses gross juice; percentages use net.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.