FireCADCalc

Tube-Side Heat Transfer Coefficient (Gnielinski, Sieder–Tate)

Film coefficient for flow inside a tube or annulus: Hausen and Sieder–Tate for laminar, Gnielinski for transition and turbulent flow (Perry's sec. 5).

Thermal power plantSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: Water 50 °C, 1.2 m/s, 20 mm tubePerry's Example 5-6: air channel, Re 8521 (Nu 25.96, h 44.75)Oil, laminar, 25 mmWater in annulus 50/25 mm, inner heated

Results

Hydraulic diameter25.000mm
Reynolds number45,155
Prandtl number3.5734
Nusselt number (Hausen laminar; Gnielinski turbulent)226.86
Film coefficient5,807.7W/(m²·K)
Nusselt number, Sieder–Tate (for comparison)232.16

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Water 50 °C, 1.2 m/s, 20 mm tube. The inputs, in the units selected above:

InputValue
GeometryRound tube
Tube inside diameter or annulus outer diameter20.000 mm
Annulus inner diameter (annulus only)10.000 mm
Heated length3.0000 m
Mean velocity1.2000 m/s
Density988.00 kg/m³
Viscosity at bulk temperature0.54700 cP
Thermal conductivity0.64000 W/(m·K)
Specific heat4.1810 kJ/(kg·K)
FluidLiquid
Viscosity at wall temperature (liquids)0.35500 cP
Bulk temperature (gases)50.000 °C
Wall temperature (gases)80.000 °C
Entrance correction (gases, Pr ≈ 1)None (fully developed)

Applying the formula below gives:

ResultValue
Hydraulic diameter20.000 mm
Reynolds number43,349
Prandtl number3.5734
Nusselt number (Hausen laminar; Gnielinski turbulent)228.09
Film coefficient7,299.0 W/(m²·K)
Nusselt number, Sieder–Tate (for comparison)224.70

Open this example in the calculator and change any input.

Formula

\(Nu = \frac{(f/2)(Re - 1000)Pr}{1 + 12.7(f/2)^{1/2}(Pr^{2/3} - 1)}K, \quad f = 0.25(0.790\ln Re - 1.64)^{-2}\)

\(Nu = 3.66 + \frac{0.0668\,Gz}{1 + 0.04\,Gz^{2/3}}, \ Gz = \frac{D}{L}RePr, \quad Nu_{ST} = 0.027Re^{0.8}Pr^{1/3}\left(\frac{\mu_b}{\mu_s}\right)^{0.14}\)

\(K = \left(\frac{Pr_b}{Pr_s}\right)^{0.11}\ \text{(liquids)}, \ \left(\frac{T_b}{T_s}\right)^{0.45}\ \text{(gases)}, \quad \frac{\overline{Nu}}{Nu} = 1 + \frac{C}{(L/D)^n}\)

Variables

Symbol Meaning SI unit
\(\text{geometry}\) Geometry -
\(D\) Tube inside diameter or annulus outer diameter m
\(D_i\) Annulus inner diameter (annulus only) m
\(L\) Heated length m
\(V\) Mean velocity m/s
\(\rho\) Density kg/m³
\(\mu_b\) Viscosity at bulk temperature Pa·s
\(k\) Thermal conductivity W/(m·K)
\(c_p\) Specific heat J/(kg·K)
\(\text{fluid}\) Fluid -
\(\mu_s\) Viscosity at wall temperature (liquids) Pa·s
\(T_b\) Bulk temperature (gases) K
\(T_s\) Wall temperature (gases) K
\(\text{entrance}\) Entrance correction (gases, Pr ≈ 1) -
\(D_h\) Hydraulic diameter m
\(Re\) Reynolds number -
\(Pr\) Prandtl number -
\(Nu\) Nusselt number (Hausen laminar; Gnielinski turbulent) -
\(h\) Film coefficient W/(m²·K)
\(Nu_{ST}\) Nusselt number, Sieder–Tate (for comparison) -

Method and standards

Gnielinski, Hausen and Sieder–Tate with Perry's corrections; Pr_s taken as Pr·μ_s/μ_b for liquids.

Where it is used

  • Shell-and-tube and double-pipe exchanger tube side.
  • Heater and cooler rating.

Common mistakes

  • Using the annulus outer diameter as D_h.
  • Properties at the wrong temperature.

Assumptions and limits

  • The gas property correction K = (T_b/T_s)^0.45 applies to heating and cooling alike over 0.5 < T_b/T_s < 1.5, as Perry's gives it; the liquid correction (Pr_b/Pr_s)^0.11 over 0.05–20. The page warns outside these ranges.

  • Entrance-configuration constants (Perry's Table 5-3) are for Pr ≈ 1; the page warns when they are applied to a fluid with Pr far from 1.

  • The Petukhov–Roizen annulus factors multiply the turbulent (Gnielinski) result only, as in Perry's; the laminar annulus uses the round-tube equations with D_h.

  • Smooth tubes; single phase.

References

  • Perry's Chemical Engineers' Handbook
  • 9th ed. (McGraw-Hill, 2019)
  • sec. 5
  • Eqs. (5-52)
  • (5-54) to (5-57) and (5-60)
  • Table 5-3 and the Petukhov–Roizen annulus factors
  • with Example 5-6

Questions and answers

Which correlation is used?

Hausen below Re 2,100; Gnielinski above, which Perry's recommends for transition and turbulent flow. Sieder–Tate is shown for comparison.

What does Perry's Example 5-6 give?

Air in a plate-exchanger channel at Re 8,521: Nu 21.7, 26.0 with entrance effects, h about 45 W/(m²·K).

What do the defaults represent?

Water at 50 °C at 1.2 m/s in a 20 mm tube heated at an 80 °C wall.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.