Worked example
Example: Water 50 °C, 1.2 m/s, 20 mm tube. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Geometry | Round tube |
| Tube inside diameter or annulus outer diameter | 20.000 mm |
| Annulus inner diameter (annulus only) | 10.000 mm |
| Heated length | 3.0000 m |
| Mean velocity | 1.2000 m/s |
| Density | 988.00 kg/m³ |
| Viscosity at bulk temperature | 0.54700 cP |
| Thermal conductivity | 0.64000 W/(m·K) |
| Specific heat | 4.1810 kJ/(kg·K) |
| Fluid | Liquid |
| Viscosity at wall temperature (liquids) | 0.35500 cP |
| Bulk temperature (gases) | 50.000 °C |
| Wall temperature (gases) | 80.000 °C |
| Entrance correction (gases, Pr ≈ 1) | None (fully developed) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hydraulic diameter | 20.000 mm |
| Reynolds number | 43,349 |
| Prandtl number | 3.5734 |
| Nusselt number (Hausen laminar; Gnielinski turbulent) | 228.09 |
| Film coefficient | 7,299.0 W/(m²·K) |
| Nusselt number, Sieder–Tate (for comparison) | 224.70 |
Open this example in the calculator and change any input.
Formula
\(Nu = \frac{(f/2)(Re - 1000)Pr}{1 + 12.7(f/2)^{1/2}(Pr^{2/3} - 1)}K, \quad f = 0.25(0.790\ln Re - 1.64)^{-2}\)
\(Nu = 3.66 + \frac{0.0668\,Gz}{1 + 0.04\,Gz^{2/3}}, \ Gz = \frac{D}{L}RePr, \quad Nu_{ST} = 0.027Re^{0.8}Pr^{1/3}\left(\frac{\mu_b}{\mu_s}\right)^{0.14}\)
\(K = \left(\frac{Pr_b}{Pr_s}\right)^{0.11}\ \text{(liquids)}, \ \left(\frac{T_b}{T_s}\right)^{0.45}\ \text{(gases)}, \quad \frac{\overline{Nu}}{Nu} = 1 + \frac{C}{(L/D)^n}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{geometry}\) | Geometry | - |
| \(D\) | Tube inside diameter or annulus outer diameter | m |
| \(D_i\) | Annulus inner diameter (annulus only) | m |
| \(L\) | Heated length | m |
| \(V\) | Mean velocity | m/s |
| \(\rho\) | Density | kg/m³ |
| \(\mu_b\) | Viscosity at bulk temperature | Pa·s |
| \(k\) | Thermal conductivity | W/(m·K) |
| \(c_p\) | Specific heat | J/(kg·K) |
| \(\text{fluid}\) | Fluid | - |
| \(\mu_s\) | Viscosity at wall temperature (liquids) | Pa·s |
| \(T_b\) | Bulk temperature (gases) | K |
| \(T_s\) | Wall temperature (gases) | K |
| \(\text{entrance}\) | Entrance correction (gases, Pr ≈ 1) | - |
| \(D_h\) | Hydraulic diameter | m |
| \(Re\) | Reynolds number | - |
| \(Pr\) | Prandtl number | - |
| \(Nu\) | Nusselt number (Hausen laminar; Gnielinski turbulent) | - |
| \(h\) | Film coefficient | W/(m²·K) |
| \(Nu_{ST}\) | Nusselt number, Sieder–Tate (for comparison) | - |
Method and standards
Gnielinski, Hausen and Sieder–Tate with Perry's corrections; Pr_s taken as Pr·μ_s/μ_b for liquids.
Where it is used
- Shell-and-tube and double-pipe exchanger tube side.
- Heater and cooler rating.
Common mistakes
- Using the annulus outer diameter as D_h.
- Properties at the wrong temperature.
Assumptions and limits
The gas property correction K = (T_b/T_s)^0.45 applies to heating and cooling alike over 0.5 < T_b/T_s < 1.5, as Perry's gives it; the liquid correction (Pr_b/Pr_s)^0.11 over 0.05–20. The page warns outside these ranges.
Entrance-configuration constants (Perry's Table 5-3) are for Pr ≈ 1; the page warns when they are applied to a fluid with Pr far from 1.
The Petukhov–Roizen annulus factors multiply the turbulent (Gnielinski) result only, as in Perry's; the laminar annulus uses the round-tube equations with D_h.
Smooth tubes; single phase.
References
- Perry's Chemical Engineers' Handbook
- 9th ed. (McGraw-Hill, 2019)
- sec. 5
- Eqs. (5-52)
- (5-54) to (5-57) and (5-60)
- Table 5-3 and the Petukhov–Roizen annulus factors
- with Example 5-6
Questions and answers
Which correlation is used?
Hausen below Re 2,100; Gnielinski above, which Perry's recommends for transition and turbulent flow. Sieder–Tate is shown for comparison.
What does Perry's Example 5-6 give?
Air in a plate-exchanger channel at Re 8,521: Nu 21.7, 26.0 with entrance effects, h about 45 W/(m²·K).
What do the defaults represent?
Water at 50 °C at 1.2 m/s in a 20 mm tube heated at an 80 °C wall.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.