Tank or Vessel Heat-up Time with a Steam Coil or Jacket

Time to heat a batch in a tank or jacketed vessel with steam, from mass, specific heat, coil or jacket area, U and steam pressure, with the steam used.

Process steam and utilitiesChemical and fertiliserPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)Tank and drum

Inputs

Examples: 10 t of water 20 to 80 °C, coil 5 m², U 800, steam 4 bar(a)Oil 30 t, 30 to 60 °C, 20 m², U 150, 7 bar(a)Process liquor 5 t, 25 to 95 °C, 3 m², U 1000, 6 bar(a)

Results

Heat losses from the tank are not included; they lengthen the time and add steam.

Heat-up time1.3269h
Steam used for the batch827.84kg
Average steam flow623.89kg/h
Heat flow at the start (peak)404.86kW
Steam saturation temperature164.95°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 t of water 20 to 80 °C, coil 5 m², U 800, steam 4 bar(a). The inputs, in the units selected above:

InputValue
Liquid in the tank10.000 t
Specific heat of the liquid4.1800 kJ/(kg·K)
Starting temperature20.000 °C
Final temperature80.000 °C
Overall heat transfer coefficient of coil or jacket800.00 W/(m²·K)
Coil or jacket area5.0000 m²
Steam pressure (absolute, saturated)4.0000 bar

Applying the formula below gives:

ResultValue
Heat-up time1.9284 h
Steam used for the batch1,175.6 kg
Average steam flow609.63 kg/h
Heat flow at the start (peak)494.45 kW
Steam saturation temperature143.61 °C

Open this example in the calculator and change any input.

Formula

\(t = \frac{m c_p}{U A}\ln\frac{T_s - T_0}{T_s - T_1} \qquad m_s = \frac{m c_p (T_1 - T_0)}{h_{fg}} \qquad \dot Q_0 = U A (T_s - T_0)\)

Variables

Symbol Meaning SI unit
\(m\) liquid mass kg
\(c_p\) specific heat J/(kg·K)
\(T_0\) starting temperature K
\(T_1\) final temperature K
\(U\) overall coefficient W/(m²·K)
\(A\) coil or jacket area m²
\(p_s\) steam pressure Pa
\(t\) heat-up time s
\(m_s\) steam for the batch kg
\(\bar{\dot m}_s\) average steam flow kg/s
\(\dot Q_0\) heat flow at the start W
\(T_s\) steam saturation temperature K
\(h_{fg}\) latent heat (IF97) J/kg

Method and standards

Lumped (well-mixed) batch heated by condensing steam at constant temperature; U constant.

Where it is used

  • Batch reactors, dissolving tanks and process vessels.
  • Sizing coils and jackets for a heat-up time.
  • Steam trap and steam supply sizing (peak load).

Common mistakes

  • Sizing steam traps on the average instead of the start-up load.
  • Ignoring tank heat loss for long heat-ups.
  • Using a U for an agitated vessel when it is not stirred.

Assumptions and limits

  • Steam enters dry and saturated and leaves as condensate at saturation temperature, so each kilogram gives up h_fg. Wet steam, sub-cooled condensate, trap losses and flash steam are not included: wet steam needs more, sub-cooling a little less.

  • Well-mixed liquid; constant U and steam temperature; no heat loss.

References

  • Transient heating with constant steam temperature (lumped batch)
  • IAPWS R7-97 IF97

Questions and answers

How long does a tank take to heat?

10 t of water from 20 to 80 °C with a 5 m² coil at U = 800 W/(m²·K) and 4 bar(a) steam takes 1.9 hours and 1176 kg of steam; the peak heat flow at the start is 495 kW.

Why does heating slow down?

The temperature difference to the steam shrinks as the batch warms, so the rate falls exponentially.

How do I speed it up?

Raise the steam pressure (hotter steam), add area, or agitate to raise U.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.