FireCADCalc

Tank Cooling Overnight: Temperature Fall and Heat Loss

Temperature of a stored liquid after a period without heating, from its mass, specific heat and the tank's UA to ambient (exponential cooling), with the heat lost.

Sugar mill and cogenerationDistillery and ethanolRefinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 50 m3 oil, 70 °C, 12 hMolasses 500 m3, bare roof

Results

Well-mixed liquid assumed; an unstirred tank stratifies, and the liquid near the outlet may cool faster than the average.

Temperature after the period43.176°C
Heat lost780.09kWh
Time constant mc_p/UA316.87h
Time to fall to the lowest acceptable temperature161.87h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 m3 oil, 70 °C, 12 h. The inputs, in the units selected above:

InputValue
Liquid volume50.000 m³
Liquid density950.00 kg/m³
Specific heat2.0000 kJ/(kg·K)
Overall coefficient to ambient1.2000 W/(m²·K)
Surface area losing heat90.000 m²
Initial temperature70.000 °C
Ambient temperature15.000 °C
Time without heating12.000 h
Lowest acceptable temperature50.000 °C

Applying the formula below gives:

ResultValue
Temperature after the period67.364 °C
Heat lost69.558 kWh
Time constant mc_p/UA244.34 h
Time to fall to the lowest acceptable temperature110.44 h

Open this example in the calculator and change any input.

Formula

\(T(t) = T_a + (T_0 - T_a)e^{-t/\tau}, \quad \tau = \frac{mc_p}{UA}, \quad t_{min} = \tau\ln\frac{T_0 - T_a}{T_{min} - T_a}\)

Variables

Symbol Meaning SI unit
\(V\) Liquid volume m³
\(\rho\) Liquid density kg/m³
\(c_p\) Specific heat J/(kg·K)
\(U\) Overall coefficient to ambient W/(m²·K)
\(A\) Surface area losing heat m²
\(T_0\) Initial temperature K
\(T_a\) Ambient temperature K
\(t\) Time without heating s
\(T_{min}\) Lowest acceptable temperature K
\(T(t)\) Temperature after the period K
\(Q\) Heat lost J
\(\tau\) Time constant mc_p/UA s
\(t_{min}\) Time to fall to the lowest acceptable temperature s

Method and standards

Lumped-capacitance cooling.

Where it is used

  • Fuel oil, molasses and wax tanks.
  • Hot water and process liquid storage.

Common mistakes

  • Using U without the outside film.
  • Ignoring the roof and bottom area.

Assumptions and limits

  • The time to the lowest acceptable temperature is shown only when that temperature lies between ambient and the starting temperature; the other results do not depend on it.

  • Well mixed; constant U and ambient.

References

  • Lumped exponential cooling (Newton's law of cooling; definitions)

Questions and answers

What is the time constant?

The time for the temperature excess over ambient to fall to 37 %: the liquid's heat capacity divided by UA.

How do I get U?

From insulation thickness and outside film coefficient; an insulated tank is typically 0.3–1 W/(m²·K), bare steel 5–15.

What do the defaults give?

50 m³ of oil at 70 °C, UA 108 W/K: about 67 °C after 12 hours (time constant about 10 days).

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.