Worked example
Example: 2 m sphere at 150 °C, 100 mm insulation. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inside temperature | 150.00 °C |
| Ambient temperature | 25.000 °C |
| Inner radius of the insulation | 1.0000 m |
| Outer radius of the insulation | 1.1000 m |
| Insulation conductivity | 0.050000 W/(m·K) |
| Inside coefficient | 500.00 W/(m²·K) |
| Outside coefficient | 10.000 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat flow | 825.51 W |
| Outer surface temperature | 30.429 °C |
| Critical radius 2k/h_o | 10.000 mm |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \frac{T_i - T_a}{\dfrac{1}{4\pi r_1^2 h_i} + \dfrac{1/r_1 - 1/r_2}{4\pi k} + \dfrac{1}{4\pi r_2^2 h_o}}, \quad T_s = T_a + \frac{\dot Q}{4\pi r_2^2 h_o}, \quad r_{cr} = \frac{2k}{h_o}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_i\) | Inside temperature | K |
| \(T_a\) | Ambient temperature | K |
| \(r_1\) | Inner radius of the insulation | m |
| \(r_2\) | Outer radius of the insulation | m |
| \(k\) | Insulation conductivity | W/(m·K) |
| \(h_i\) | Inside coefficient | W/(m²·K) |
| \(h_o\) | Outside coefficient | W/(m²·K) |
| \(\dot Q\) | Heat flow | W |
| \(T_s\) | Outer surface temperature | K |
| \(r_{cr}\) | Critical radius 2k/h_o | m |
Method and standards
Steady radial conduction.
Where it is used
- Spheres, LPG and cryogenic tanks.
- Heat transfer examinations.
Common mistakes
- Diameter for radius.
- Cylindrical formula.
Assumptions and limits
- Steady, uniform insulation.
- The critical radius is compared with r₁ and r₂: below it, more insulation increases the loss, and the page warns (this matters only for small spheres or poor insulation).
References
- Radial conduction in a sphere
- R = (1/r₁ − 1/r₂)/(4πk) (Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer, ch. 3)
Questions and answers
A 2 m sphere at 150 °C with 100 mm of insulation (k 0.05)?
About 0.83 kW lost.
What is the critical radius for a sphere?
2k/h: twice the cylinder value.
Why does the inside coefficient barely matter?
The insulation's resistance dominates.