Heat Loss Through a Spherical Shell

Heat flow and surface temperature of an insulated spherical vessel from radii, conductivity and inside and outside coefficients, with the critical radius.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 2 m sphere at 150 °C, 100 mm insulationLPG sphere 6 m, 50 mm, cold 0 °C in 35 °CSmall 100 mm sphere, 20 mm, 80 °C

Results

Heat flow-2,294.8W
Outer surface temperature33.364°C
Critical radius 2k/h_o5.0000mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 m sphere at 150 °C, 100 mm insulation. The inputs, in the units selected above:

InputValue
Inside temperature150.00 °C
Ambient temperature25.000 °C
Inner radius of the insulation1.0000 m
Outer radius of the insulation1.1000 m
Insulation conductivity0.050000 W/(m·K)
Inside coefficient500.00 W/(m²·K)
Outside coefficient10.000 W/(m²·K)

Applying the formula below gives:

ResultValue
Heat flow825.51 W
Outer surface temperature30.429 °C
Critical radius 2k/h_o10.000 mm

Open this example in the calculator and change any input.

Formula

\(\dot Q = \frac{T_i - T_a}{\dfrac{1}{4\pi r_1^2 h_i} + \dfrac{1/r_1 - 1/r_2}{4\pi k} + \dfrac{1}{4\pi r_2^2 h_o}}, \quad T_s = T_a + \frac{\dot Q}{4\pi r_2^2 h_o}, \quad r_{cr} = \frac{2k}{h_o}\)

Variables

Symbol Meaning SI unit
\(T_i\) Inside temperature K
\(T_a\) Ambient temperature K
\(r_1\) Inner radius of the insulation m
\(r_2\) Outer radius of the insulation m
\(k\) Insulation conductivity W/(m·K)
\(h_i\) Inside coefficient W/(m²·K)
\(h_o\) Outside coefficient W/(m²·K)
\(\dot Q\) Heat flow W
\(T_s\) Outer surface temperature K
\(r_{cr}\) Critical radius 2k/h_o m

Method and standards

Steady radial conduction.

Where it is used

  • Spheres, LPG and cryogenic tanks.
  • Heat transfer examinations.

Common mistakes

  • Diameter for radius.
  • Cylindrical formula.

Assumptions and limits

  • Steady, uniform insulation.
  • The critical radius is compared with r₁ and r₂: below it, more insulation increases the loss, and the page warns (this matters only for small spheres or poor insulation).

References

  • Radial conduction in a sphere
  • R = (1/r₁ − 1/r₂)/(4πk) (Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer, ch. 3)

Questions and answers

A 2 m sphere at 150 °C with 100 mm of insulation (k 0.05)?

About 0.83 kW lost.

What is the critical radius for a sphere?

2k/h: twice the cylinder value.

Why does the inside coefficient barely matter?

The insulation's resistance dominates.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators