Flat-Plate Solar Collector Efficiency (Hottel–Whillier–Bliss)

Efficiency and useful heat of a flat-plate solar water collector from irradiance, inlet and ambient temperatures and the collector's F_R(τα) and F_R U_L.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 800 W/m², inlet 40 °C, ambient 30 °C, 2 m²Low sun 400 W/m², inlet 60 °C, ambient 20 °CEvacuated-tube-like 900 W/m², 80 °C, 25 °C, F_R U_L 1.5

From the collector's test report. ISO 9806 reports often give η₀, a₁, a₂ on the mean fluid temperature: convert them to the inlet-temperature form F_R(τα), F_R U_L first (Duffie and Beckman).

Results

Linear efficiency line from the test report; second-order loss terms and incidence-angle effects are not included.

Efficiency69.375%
Useful heat1,110.0W
Reduced temperature0.012500m²·K/W
Inlet temperature at zero output163.33°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 800 W/m², inlet 40 °C, ambient 30 °C, 2 m². The inputs, in the units selected above:

InputValue
Solar irradiance on the collector800.00 W/m²
Inlet water temperature40.000 °C
Ambient temperature30.000 °C
Optical intercept F_R(τα)75.000 %
Loss slope F_R U_L4.5000 W/(m²·K)
Collector aperture area2.0000 m²

Applying the formula below gives:

ResultValue
Efficiency69.375 %
Useful heat1,110.0 W
Reduced temperature0.012500 m²·K/W
Inlet temperature at zero output163.33 °C

Open this example in the calculator and change any input.

Formula

\(\eta = F_R(\tau\alpha) - F_R U_L\,\frac{T_i - T_a}{G}, \quad \dot Q_u = \eta\, G\, A, \quad T_{stag} = T_a + \frac{F_R(\tau\alpha)\,G}{F_R U_L}\)

Variables

Symbol Meaning SI unit
\(G\) Solar irradiance on the collector W/m²
\(T_i\) Inlet water temperature K
\(T_a\) Ambient temperature K
\(F_R(\tau\alpha)\) Optical intercept F_R(τα) -
\(F_R U_L\) Loss slope F_R U_L W/(m²·K)
\(A\) Collector aperture area m²
\(\eta\) Efficiency -
\(\dot Q_u\) Useful heat W
\((T_i - T_a)/G\) Reduced temperature m²·K/W
\(T_{stag}\) Inlet temperature at zero output K

Method and standards

Hottel–Whillier–Bliss equation.

Where it is used

  • Solar water heating design.
  • Comparing collectors.

Common mistakes

  • Using outlet instead of inlet temperature.
  • Gross instead of aperture area.

Assumptions and limits

  • Steady state, linear loss, on the inlet temperature. Test reports to ISO 9806 usually give η₀, a₁ and a₂ on the mean fluid temperature; those must be converted to F_R(τα) and F_R U_L before use here.
  • With F_R U_L = 0 the zero-output temperature is not defined and is not shown.

References

  • Hottel–Whillier–Bliss equation (Duffie and Beckman, Solar Engineering of Thermal Processes, ch. 6)

Questions and answers

800 W/m², inlet 40 °C, ambient 30 °C?

Efficiency 69.4 %; 1110 W from 2 m².

Why does efficiency fall with temperature?

Losses grow with the collector-to-ambient difference.

Where are F_R(τα) and F_R U_L found?

In the collector's certified test report.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.