FireCADCalc

Radiation Heat Exchange with Radiation Shields

Radiant heat flux between two large parallel plates and the reduction by thin radiation shields between them, with all surfaces of equal or set emissivity.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 800 K to 400 K, ε 0.8, one 0.1 shieldSame, three shieldsNo shield, 1 200 K to 300 K, ε 0.9 and 0.5

Results

Large parallel grey surfaces; each shield adds (2/ε_s − 1) to the resistance.

Flux without shields55,479W/m²
Flux with the shields55,479W/m²
Reduction0%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 800 K to 400 K, ε 0.8, one 0.1 shield. The inputs, in the units selected above:

InputValue
Temperature of the hot plate526.85 °C
Temperature of the cold plate126.85 °C
Emissivity of plate 10.80000 -
Emissivity of plate 20.80000 -
Emissivity of each shield (both faces)0.10000 -
Number of shields1.0000 -

Applying the formula below gives:

ResultValue
Flux without shields14,516 W/m²
Flux with the shields1,062.2 W/m²
Reduction92.683 %

Open this example in the calculator and change any input.

Formula

\(q'' = \frac{\sigma(T_1^4 - T_2^4)}{\dfrac{1}{\varepsilon_1} + \dfrac{1}{\varepsilon_2} - 1 + N\left(\dfrac{2}{\varepsilon_s} - 1\right)}\)

Variables

Symbol Meaning SI unit
\(T_1\) Temperature of the hot plate K
\(T_2\) Temperature of the cold plate K
\(\varepsilon_1\) Emissivity of plate 1 -
\(\varepsilon_2\) Emissivity of plate 2 -
\(\varepsilon_s\) Emissivity of each shield (both faces) -
\(N\) Number of shields -
\(q''_0\) Flux without shields W/m²
\(q''\) Flux with the shields W/m²
\(1 - q''/q''_0\) Reduction -

Method and standards

Radiation network with shields.

Where it is used

  • Furnace and oven design.
  • Thermocouple shielding.

Common mistakes

  • °C in T⁴.
  • Applying to small enclosed bodies.

Assumptions and limits

  • Large parallel grey surfaces.
  • The number of shields is a whole number; a fractional entry is rounded, with a note.

References

  • Incropera
  • DeWitt
  • Bergman and Lavine
  • Fundamentals of Heat and Mass Transfer
  • ch. 13 (radiation shields between parallel plates)

Questions and answers

800 K to 400 K, ε 0.8 each; one shield of ε 0.1?

The flux falls from about 14.5 kW/m² to about 1.1 kW/m²: a 93 % cut.

Why low-emissivity shields?

Each shield adds a resistance of 2/ε_s − 1.

Where are shields used?

Thermocouple radiation shields, furnace doors, multi-layer insulation.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.