Worked example
Example: 800 K to 400 K, ε 0.8, one 0.1 shield. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Temperature of the hot plate | 526.85 °C |
| Temperature of the cold plate | 126.85 °C |
| Emissivity of plate 1 | 0.80000 - |
| Emissivity of plate 2 | 0.80000 - |
| Emissivity of each shield (both faces) | 0.10000 - |
| Number of shields | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Flux without shields | 14,516 W/m² |
| Flux with the shields | 1,062.2 W/m² |
| Reduction | 92.683 % |
Open this example in the calculator and change any input.
Formula
\(q'' = \frac{\sigma(T_1^4 - T_2^4)}{\dfrac{1}{\varepsilon_1} + \dfrac{1}{\varepsilon_2} - 1 + N\left(\dfrac{2}{\varepsilon_s} - 1\right)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_1\) | Temperature of the hot plate | K |
| \(T_2\) | Temperature of the cold plate | K |
| \(\varepsilon_1\) | Emissivity of plate 1 | - |
| \(\varepsilon_2\) | Emissivity of plate 2 | - |
| \(\varepsilon_s\) | Emissivity of each shield (both faces) | - |
| \(N\) | Number of shields | - |
| \(q''_0\) | Flux without shields | W/m² |
| \(q''\) | Flux with the shields | W/m² |
| \(1 - q''/q''_0\) | Reduction | - |
Method and standards
Radiation network with shields.
Where it is used
- Furnace and oven design.
- Thermocouple shielding.
Common mistakes
- °C in T⁴.
- Applying to small enclosed bodies.
Assumptions and limits
- Large parallel grey surfaces.
- The number of shields is a whole number; a fractional entry is rounded, with a note.
References
- Incropera
- DeWitt
- Bergman and Lavine
- Fundamentals of Heat and Mass Transfer
- ch. 13 (radiation shields between parallel plates)
Questions and answers
800 K to 400 K, ε 0.8 each; one shield of ε 0.1?
The flux falls from about 14.5 kW/m² to about 1.1 kW/m²: a 93 % cut.
Why low-emissivity shields?
Each shield adds a resistance of 2/ε_s − 1.
Where are shields used?
Thermocouple radiation shields, furnace doors, multi-layer insulation.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.