Worked example
Example: Economiser tube: gas 60, water 5000 W/(m²K), 51 x 4.5 mm steel. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Outside film coefficient | 60.000 W/(m²·K) |
| Inside film coefficient | 5,000.0 W/(m²·K) |
| Tube outside diameter | 51.000 mm |
| Tube inside diameter | 42.000 mm |
| Wall thermal conductivity | 45.000 W/(m·K) |
| Outside fouling resistance (on the outside area) | 5.0000e-04 m²·K/W |
| Inside fouling resistance (on the inside area) | 1.0000e-04 m²·K/W |
Applying the formula below gives:
| Result | Value |
|---|---|
| U on the outside area | 56.686 W/(m²·K) |
| U on the inside area | 68.833 W/(m²·K) |
| Total resistance (outside area basis) | 0.017641 m²·K/W |
| Share of the wall in the resistance | 0.62367 % |
Open this example in the calculator and change any input.
Formula
\(\frac{1}{U_o} = \frac{1}{h_o} + R_{fo} + \frac{d_o \ln(d_o/d_i)}{2 k_w} + R_{fi}\frac{d_o}{d_i} + \frac{d_o}{d_i\,h_i} \qquad U_i = U_o\,\frac{d_o}{d_i} \qquad R_o = \frac{1}{U_o}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(h_o\) | outside film coefficient | W/(m²·K) |
| \(h_i\) | inside film coefficient | W/(m²·K) |
| \(d_o\) | outside diameter | m |
| \(d_i\) | inside diameter | m |
| \(k_w\) | wall conductivity | W/(m·K) |
| \(R_{fo}\) | outside fouling resistance | m²·K/W |
| \(R_{fi}\) | inside fouling resistance | m²·K/W |
| \(U_o\) | U on outside area | W/(m²·K) |
| \(U_i\) | U on inside area | W/(m²·K) |
| \(R_o\) | total resistance | m²·K/W |
| \(s_w\) | wall share of resistance | – |
Method and standards
Resistances in series for a cylindrical wall, referred to the outside area.
Where it is used
- Economiser, air heater, condenser and process exchanger design.
- Checking the effect of fouling and cleaning.
- Back-calculating fouling from plant data.
Common mistakes
- Mixing inside and outside area bases.
- Ignoring fouling, or adding it twice through a fouled film coefficient.
- Using a gas coefficient for clean tubes on a sooty boiler.
Assumptions and limits
- Thin or thick wall (log-mean conduction); no fins (use the finned-tube calculator for the gas side).
References
- Thermal resistances in series for a cylindrical wall
Questions and answers
How is U calculated for a tube?
Add the resistances on one area basis. An economiser tube 51 × 4.5 mm with 60 W/(m²·K) outside, 5000 inside and fouling of 0.0005 and 0.0001 m²·K/W has U = 56.7 W/(m²·K) on the outside area.
Why is U close to the gas coefficient?
The gas side has by far the largest resistance; improving the water side hardly changes U, while fins on the gas side do.
Outside or inside area?
Either, as long as the area used with U matches; U_o A_o = U_i A_i.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.