FireCADCalc

Transient Heating or Cooling: Lumped Capacitance

Time for a small body to heat or cool to a temperature in a fluid, or its temperature after a time, with the Biot number check, by the lumped capacitance method.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Steel part 600 to 100 °C in 30 °C air, h 50Copper ball 10 mm from 20 °C heated in 90 °C water, h 500Thermocouple bead 1 mm, 25 to 199 °C in 200 °C gas, h 400

Results

Biot number h L_c / k, L_c = V/A0.003333
Time constant ρ V c_p/(h A)1.4167s
Time to reach the temperature wanted7.3168s
Temperature after the time given157.35°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Steel part 600 to 100 °C in 30 °C air, h 50. The inputs, in the units selected above:

InputValue
Initial temperature of the body600.00 °C
Fluid temperature30.000 °C
Temperature wanted (for the time)100.00 °C
Time (for the temperature)600.00 s
Convection coefficient50.000 W/(m²·K)
Volume of the body1.0000e-04 m³
Surface area0.012000 m²
Density7,850.0 kg/m³
Specific heat0.49000 kJ/(kg·K)
Conductivity of the body (for the Biot number)45.000 W/(m·K)

Applying the formula below gives:

ResultValue
Biot number h L_c / k, L_c = V/A0.009259
Time constant ρ V c_p/(h A)641.08 s
Time to reach the temperature wanted1,344.4 s
Temperature after the time given253.57 °C

Open this example in the calculator and change any input.

Formula

\(\frac{T - T_\infty}{T_i - T_\infty} = e^{-t/\tau}, \quad \tau = \frac{\rho V c_p}{h A_s}, \quad Bi = \frac{h V/A_s}{k}\)

Variables

Symbol Meaning SI unit
\(T_i\) Initial temperature of the body K
\(T_\infty\) Fluid temperature K
\(T\) Temperature wanted (for the time) K
\(t\) Time (for the temperature) s
\(h\) Convection coefficient W/(m²·K)
\(V\) Volume of the body m³
\(A_s\) Surface area m²
\(\rho\) Density kg/m³
\(c_p\) Specific heat J/(kg·K)
\(k\) Conductivity of the body (for the Biot number) W/(m·K)
\(Bi\) Biot number h L_c / k, L_c = V/A -
\(\tau\) Time constant ρ V c_p/(h A) s
\(t_T\) Time to reach the temperature wanted s
\(T_t\) Temperature after the time given K

Method and standards

Energy balance on a uniform-temperature body.

Where it is used

  • Cooling of castings, forgings and sensors.
  • Heat transfer examinations.

Common mistakes

  • Ignoring the Biot check.
  • Constant h assumed through large changes.

Assumptions and limits

  • Uniform body temperature, constant h. Results are still given when Bi > 0.1 (with a note), but they are then approximate.
  • h must include radiation where it matters: for a hot body in air (for example steel at several hundred °C) radiation dominates, so add h_r = εσ(T_s² + T_∞²)(T_s + T_∞) to the convective h.

References

  • Incropera
  • DeWitt
  • Bergman and Lavine
  • Fundamentals of Heat and Mass Transfer
  • ch. 5 (lumped capacitance)

Questions and answers

A small steel part from 600 °C to 100 °C in 30 °C air (h 50)?

Time constant about 640 s; about 22 minutes.

When is lumped valid?

Biot number below 0.1: internal gradients are small.

Why is quenching in water faster?

h is hundreds of times larger, but then Bi often exceeds 0.1.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.