FireCADCalc

LMTD Correction Factor F for a 1-2 Shell and Tube Exchanger

Correction factor F for one shell pass and two (or any even number of) tube passes from the four terminal temperatures (Bowman), with P, R and the corrected LMTD.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Hot 150→90 °C, cold 30→70 °CEqual capacities 120→80, 40→80 °CClose approach 100→60, 20→50 °C

Results

Thermal effectiveness of the cold side0.33333
Capacity ratio1.5000
Correction factor0.91048
Counterflow LMTD69.521K
Corrected mean temperature difference63.298K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Hot 150→90 °C, cold 30→70 °C. The inputs, in the units selected above:

InputValue
Hot fluid in150.00 °C
Hot fluid out90.000 °C
Cold fluid in30.000 °C
Cold fluid out70.000 °C

Applying the formula below gives:

ResultValue
Thermal effectiveness of the cold side0.33333
Capacity ratio1.5000
Correction factor0.91048
Counterflow LMTD69.521 K
Corrected mean temperature difference63.298 K

Open this example in the calculator and change any input.

Formula

\(P = \frac{t_2 - t_1}{T_1 - t_1}, \ R = \frac{T_1 - T_2}{t_2 - t_1}, \quad F = \frac{\sqrt{R^2 + 1}\,\ln\dfrac{1 - P}{1 - RP}}{(R - 1)\ln\dfrac{2 - P(R + 1 - \sqrt{R^2 + 1})}{2 - P(R + 1 + \sqrt{R^2 + 1})}}\)

Variables

Symbol Meaning SI unit
\(T_{h,in}\) Hot fluid in K
\(T_{h,out}\) Hot fluid out K
\(T_{c,in}\) Cold fluid in K
\(T_{c,out}\) Cold fluid out K
\(P\) Thermal effectiveness of the cold side -
\(R\) Capacity ratio -
\(F\) Correction factor -
\(\Delta T_{lm,cf}\) Counterflow LMTD K
\(F\,\Delta T_{lm}\) Corrected mean temperature difference K

Method and standards

Bowman's analytic result for one shell pass and an even number of tube passes.

Where it is used

  • Shell and tube exchanger design.
  • Heat transfer examinations.

Common mistakes

  • Swapping hot and cold sides in P and R.
  • Using it for two shell passes.

Assumptions and limits

  • Constant U and properties. Within 10⁻⁶ of R = 1 the R = 1 limit form is used, avoiding loss of digits.

References

  • R.A. Bowman
  • A.C. Mueller and W.M. Nagle
  • Trans. ASME 62 (1940) 283; TEMA and Kern
  • Process Heat Transfer

Questions and answers

Hot 150→90 °C, cold 30→70 °C?

P = 0.33, R = 1.5, F about 0.91.

What does F < 1 mean?

Part of the flow is co-current, so the mean driving force is less than pure counterflow.

When to add a shell?

When F falls below about 0.75–0.8.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.