FireCADCalc

Dimensionless Numbers: Re, Pr, Gr, Ra and Nu for Air or Water

Reynolds, Prandtl, Grashof, Rayleigh, Péclet and Nusselt numbers for air or water at a state, from a length, velocity, temperature difference and h.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Air at 50 °C, 50 mm, 2 m/s, 30 K, h 25Water at 50 °C, 25 mm, 1 m/s, 10 K, h 3 000Hot air 300 °C, 1 m, 0.5 m/s, 100 K, h 8

Results

β is 1/T for air (ideal gas) and from the IF97 density change for water.

Reynolds number v L/ν10,490
Prandtl number0.74447
Grashof number g β ΔT L³/ν²7.5314e+08
Rayleigh number Gr Pr5.6070e+08
Péclet number Re Pr7,809.7
Nusselt number h L/k194.20

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Air at 50 °C, 50 mm, 2 m/s, 30 K, h 25. The inputs, in the units selected above:

InputValue
FluidAir (dry)
Fluid temperature (film)50.000 °C
Pressure (absolute)1.0132 bar
Characteristic length50.000 mm
Velocity2.0000 m/s
Temperature difference (for Gr)30.000 K
Convection coefficient (for Nu)25.000 W/(m²·K)

Applying the formula below gives:

ResultValue
Reynolds number v L/ν5,595.5
Prandtl number0.73717
Grashof number g β ΔT L³/ν²356,303
Rayleigh number Gr Pr262,656
Péclet number Re Pr4,124.8
Nusselt number h L/k46.908

Open this example in the calculator and change any input.

Formula

\(Re = \frac{vL}{\nu}, \quad Pr = \frac{c_p\mu}{k}, \quad Gr = \frac{g\beta\Delta T L^3}{\nu^2}, \quad Ra = Gr\,Pr, \quad Nu = \frac{hL}{k}\)

Variables

Symbol Meaning SI unit
\(\text{fluid}\) Fluid -
\(T\) Fluid temperature (film) K
\(p\) Pressure (absolute) Pa
\(L\) Characteristic length m
\(v\) Velocity m/s
\(\Delta T\) Temperature difference (for Gr) K
\(h\) Convection coefficient (for Nu) W/(m²·K)
\(Re\) Reynolds number v L/ν -
\(Pr\) Prandtl number -
\(Gr\) Grashof number g β ΔT L³/ν² -
\(Ra\) Rayleigh number Gr Pr -
\(Pe\) Péclet number Re Pr -
\(Nu\) Nusselt number h L/k -

Method and standards

Definitions.

Where it is used

  • Choosing correlations.
  • Heat transfer examinations.

Common mistakes

  • Wrong characteristic length.
  • Properties at the wrong temperature.

Assumptions and limits

  • Single-phase fluid. Where the water expansion coefficient cannot be found (within 0.5 K of saturation or freezing) Gr and Ra are not shown.

References

  • Definitions (Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer)
  • Air from NIST Shomate
  • Sutherland and Eucken (engine); water from IAPWS-IF97 and the IAPWS 2008/2011 transport releases

Questions and answers

What is Pr for air and water at 50 °C?

About 0.74 for air with these property models (handbooks give 0.70) and 3.6 for water.

When is natural convection important?

When Gr/Re² is near or above 1.

What is the Péclet number?

Re × Pr: advection against conduction.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.