FireCADCalc

Forced Convection over a Flat Plate (Laminar and Turbulent)

Average convection coefficient over a flat plate in parallel flow of air or water, with laminar, mixed and turbulent boundary layers, from velocity and length.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: Air 10 m/s over 1 m at 60 °CAir 2 m/s over 0.3 m (laminar)Water 0.5 m/s over 0.5 m at 50 °CAir 30 m/s over 2 m, tripped (turbulent from the leading edge)

Results

Mixed boundary layer: laminar to Re 5 × 10⁵, then turbulent.

Reynolds number591,470
Average Nusselt number598.64
Average convection coefficient15.566W/(m²·K)
Heat flux622.65W/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Air 10 m/s over 1 m at 60 °C. The inputs, in the units selected above:

InputValue
FluidAir (dry)
Free-stream velocity10.000 m/s
Plate length in the flow direction1.0000 m
Surface temperature60.000 °C
Fluid temperature20.000 °C
Pressure (absolute)1.0132 bar
Boundary layerLaminar from the leading edge, transition at Re 5 × 10⁵

Applying the formula below gives:

ResultValue
Reynolds number591,470
Average Nusselt number598.64
Average convection coefficient15.566 W/(m²·K)
Heat flux622.65 W/m²

Open this example in the calculator and change any input.

Formula

\(\overline{Nu}_L = 0.664 Re_L^{1/2} Pr^{1/3}\ (\text{laminar}), \quad \overline{Nu}_L = (0.037 Re_L^{4/5} - 871) Pr^{1/3}\ (\text{mixed}), \quad \overline{Nu}_L = 0.037 Re_L^{4/5} Pr^{1/3}\ (\text{turbulent from the leading edge})\) \(Re_L = \frac{u_\infty L}{\nu}, \quad \bar h = \frac{\overline{Nu}_L k}{L}, \quad q = \bar h (T_s - T_\infty)\)

Variables

Symbol Meaning SI unit
\(\text{fluid}\) Fluid -
\(u_\infty\) Free-stream velocity m/s
\(L\) Plate length in the flow direction m
\(T_s\) Surface temperature K
\(T_\infty\) Fluid temperature K
\(p\) Pressure (absolute) Pa
\(\text{boundary layer}\) Boundary layer (laminar with transition, or tripped turbulent) -
\(Re_L\) Reynolds number -
\(Nu_L\) Average Nusselt number -
\(\bar h\) Average convection coefficient W/(m²·K)
\(q''\) Heat flux W/m²

Method and standards

Boundary layer correlations.

Where it is used

  • Air-cooled panels and fins.
  • Heat transfer examinations.

Common mistakes

  • Properties at free-stream temperature.
  • Ignoring transition.

Assumptions and limits

  • Smooth isothermal plate, Pr 0.6–60 (flagged outside), Re up to about 10⁸ (flagged above).
  • Properties at the film temperature (T_s + T_∞)/2.
  • Choose a tripped (fully turbulent) boundary layer when a leading-edge disturbance makes the flow turbulent from the start.
  • Single-phase: a water surface at or above saturation (boiling) is flagged.

References

  • Incropera
  • DeWitt
  • Bergman and Lavine
  • Fundamentals of Heat and Mass Transfer
  • ch. 7 (Nu = 0.664 Re^½ Pr^⅓ laminar; (0.037 Re^0.8 − 871) Pr^⅓ mixed, Re_c = 5 × 10⁵)
  • Air from NIST Shomate
  • Sutherland and Eucken (engine); water from IAPWS-IF97 and the IAPWS 2008/2011 transport releases

Questions and answers

Air at 10 m/s over a 1 m plate at 60 °C?

Re about 5.9 × 10⁵ (mixed): h about 16 W/(m²·K).

Where is transition?

At Re about 5 × 10⁵ for a smooth plate; disturbances trip it earlier.

Is it valid for water?

Yes, for Pr from 0.6 to 60.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.