FireCADCalc

Finned Tube Weight per Metre (Solid or Serrated Fins)

Mass per metre of solid or serrated helical fins and of the bare tube from tube size, fin height, thickness, density and material factor (Ganapathy Eqs. 64–65).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperEconomiser and air preheater

Inputs

Examples: Ganapathy: 2 in, 5 fins/in, solid CSSerrated SS 409, 1.5 in

Results

Fin mass per metre3.3351kg/m
Tube mass per metre2.2768kg/m
Finned tube mass per metre5.6119kg/m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: 2 in, 5 fins/in, solid CS. The inputs, in the units selected above:

InputValue
Tube outer diameter50.800 mm
Average tube wall thickness3.0480 mm
Fin height19.050 mm
Fin thickness1.2700 mm
Fin density (fins per metre)196.85 -
Tube material factor (0 = same as the fins)Same as the fins
Fin typeSolid
Fin material factorCarbon steel and alloys (1.0)

Applying the formula below gives:

ResultValue
Fin mass per metre8.5229 kg/m
Tube mass per metre3.5856 kg/m
Finned tube mass per metre12.109 kg/m

Open this example in the calculator and change any input.

Formula

\(W_f = 10.68\,F\,b\,n\,(d_o + h)(h + 0.03) \ \text{(solid)}, \quad W_f = 10.68\,F\,b\,n\,d_o(h + 0.12) \ \text{(serrated)}, \quad W_t = 10.68\,F_t\,d_m t_w \ \ (\mathrm{lb/ft};\ in)\)

Variables

Symbol Meaning SI unit
\(d_o\) Tube outer diameter m
\(t_w\) Average tube wall thickness m
\(h\) Fin height m
\(b\) Fin thickness m
\(n\) Fin density (fins per metre) -
\(\text{type}\) Fin type -
\(F\) Fin material factor -
\(F_t\) Tube material factor (0 = same as the fins) -
\(W_f\) Fin mass per metre kg/m
\(W_t\) Tube mass per metre kg/m
\(W\) Finned tube mass per metre kg/m

Method and standards

Ganapathy's Eqs. (64)–(65) converted to SI.

Where it is used

  • HRSG and economiser weight estimates.
  • Support and lifting design.

Common mistakes

  • Entering fins per inch as fins per metre.
  • Forgetting the tube itself.

Assumptions and limits

  • Helical fins; steel density basis.
  • Fins and tube may be of different materials (for example carbon-steel tube with stainless fins); with F_t = 0 the tube uses the fin factor.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q4.25
  • Eqs. (64a)
  • (64b)
  • (65) and Table 4.20 (material factors)

Questions and answers

Why does fin width not matter for serrated fins?

Ganapathy's formula: the segment width does not change the mass, only the slit allowance (h + 0.12 in).

Where does 10.68 come from?

Steel density 0.283 lb/in³ times π times 12 in/ft.

What does Ganapathy's example give?

2 in tube, 5 fins/in, 0.75 in × 0.05 in solid fins: about 5.7 lb/ft of fins plus 2.4 lb/ft of tube.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.