FireCADCalc

Convection from a Cylinder in Cross Flow (Churchill–Bernstein)

Average convection coefficient of a cylinder or pipe in cross flow of air or water by the Churchill–Bernstein correlation, with the heat loss per metre.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserIAPWS-IF97 (water and steam)

Inputs

Examples: 50 mm pipe at 100 °C in 5 m/s windThermowell 20 mm in water at 1 m/sWire 1 mm at 200 °C in 2 m/s air

Results

Properties at the film temperature; single cylinder (tube banks have their own correlations).

Reynolds number83.122
Average Nusselt number4.8200
Average convection coefficient146.40W/(m²·K)
Heat flow per metre82.786W/m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 mm pipe at 100 °C in 5 m/s wind. The inputs, in the units selected above:

InputValue
FluidAir (dry)
Approach velocity5.0000 m/s
Outside diameter50.000 mm
Surface temperature100.00 °C
Fluid temperature20.000 °C
Pressure (absolute)1.0132 bar

Applying the formula below gives:

ResultValue
Reynolds number13,258
Average Nusselt number63.701
Average convection coefficient34.763 W/(m²·K)
Heat flow per metre436.84 W/m

Open this example in the calculator and change any input.

Formula

\(\overline{Nu}_D = 0.3 + \frac{0.62 Re_D^{1/2} Pr^{1/3}}{\left[1 + (0.4/Pr)^{2/3}\right]^{1/4}}\left[1 + \left(\frac{Re_D}{282\,000}\right)^{5/8}\right]^{4/5}\)

Variables

Symbol Meaning SI unit
\(\text{fluid}\) Fluid -
\(V\) Approach velocity m/s
\(D\) Outside diameter m
\(T_s\) Surface temperature K
\(T_\infty\) Fluid temperature K
\(p\) Pressure (absolute) Pa
\(Re_D\) Reynolds number -
\(Nu_D\) Average Nusselt number -
\(\bar h\) Average convection coefficient W/(m²·K)
\(q'\) Heat flow per metre W/m

Method and standards

Churchill–Bernstein correlation.

Where it is used

  • Outdoor pipe losses.
  • Thermowell and sensor heat transfer.

Common mistakes

  • Using tube-bank values for a single tube.
  • Free-stream properties.

Assumptions and limits

  • Single cylinder, uniform approach flow.
  • Single-phase: for water a surface at or above the saturation temperature (boiling) is flagged.

References

  • S.W. Churchill and M. Bernstein
  • J. Heat Transfer 99 (1977) 300
  • Incropera
  • DeWitt
  • Bergman and Lavine
  • Fundamentals of Heat and Mass Transfer
  • ch. 7
  • Air from NIST Shomate
  • Sutherland and Eucken (engine); water from IAPWS-IF97 and the IAPWS 2008/2011 transport releases

Questions and answers

A 50 mm pipe at 100 °C in a 5 m/s wind?

Re about 1.3 × 10⁴, h about 35 W/(m²·K), roughly 440 W per metre.

Why does wind raise heat loss so much?

Forced convection is several times natural convection.

Valid for which range?

All Re·Pr above 0.2.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.