Worked example
Example: 10 mm cable, PVC k 0.2, h 10, 5 mm insulation (below r_c). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Insulation thermal conductivity | 0.20000 W/(m·K) |
| Outside surface heat transfer coefficient | 10.000 W/(m²·K) |
| Pipe or wire outer diameter | 10.000 mm |
| Insulation thickness | 5.0000 mm |
| Pipe surface temperature | 80.000 °C |
| Ambient temperature | 25.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Critical radius | 20.000 mm |
| Critical outer diameter | 40.000 mm |
| Heat loss per metre, bare | 17.279 W/m |
| Heat loss per metre, insulated | 25.663 W/m |
| Insulated loss as a share of bare | 148.53 % |
Open this example in the calculator and change any input.
Formula
\(r_c = \frac{k}{h}\)
\(q'_0 = 2\pi r_1 h (T_s - T_a)\)
\(q' = \frac{T_s - T_a}{\frac{\ln(r_2/r_1)}{2\pi k} + \frac{1}{2\pi r_2 h}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(k\) | insulation conductivity | W/(m·K) |
| \(h\) | outside surface coefficient | W/(m²·K) |
| \(D\) | pipe or wire outer diameter | m |
| \(t\) | insulation thickness | m |
| \(T_s\) | pipe surface temperature | K |
| \(T_a\) | ambient temperature | K |
| \(r_1\) | pipe radius | m |
| \(r_2\) | outer radius of insulation | m |
| \(r_c\) | critical radius | m |
| \(D_c\) | critical diameter | m |
| \(q'_0\) | heat loss per metre, bare | W/m |
| \(q'\) | heat loss per metre, insulated | W/m |
| \(q' / q'_0\) | insulated loss over bare loss | - |
Method and standards
Heat loss through a cylindrical insulation layer is a balance of conduction resistance, which grows with thickness, and surface resistance, which shrinks as the outer area grows. The loss is greatest at the critical radius k/h.
Where it is used
- Checking insulation on small tubes, tracers and cables.
- Explaining why thin insulation on wires helps cooling.
- Teaching the conduction–convection trade-off.
Common mistakes
- Applying it to large pipes where it never matters.
- Using a different h for bare and insulated without saying so.
- Ignoring radiation in h for hot surfaces.
Assumptions and limits
- Same h on bare and insulated surfaces; steady state.
References
- r_c = k/h (cylinder)
Questions and answers
What is the critical radius of PVC insulation in still air?
k/h = 0.2/10 = 20 mm. A 10 mm cable with 5 mm of PVC loses about 48 % more heat than bare: useful for cooling cables.
Does this matter for steam pipes?
Rarely. With mineral wool (k 0.04) the critical radius is about 4 mm, far smaller than any pipe, so insulation always reduces loss.
Why can insulation increase heat loss?
On a thin pipe it adds outer surface faster than it adds resistance, until the outer radius passes r_c.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.