FireCADCalc

Critical Radius of Insulation

Critical radius of insulation on a pipe or wire (k/h), and whether a chosen insulation thickness raises or lowers the heat loss compared with the bare pipe.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 10 mm cable, PVC k 0.2, h 10, 5 mm insulation (below r_c)DN50 pipe (60.3 mm), wool k 0.04, h 10, 25 mm6 mm tube, k 0.15, h 8, 3 mm

Results

The same outside coefficient h is used bare and insulated; in practice h changes a little with diameter and surface temperature.

The pipe is smaller than the critical radius: thin insulation increases the heat loss until the outer radius passes well beyond r_c.

Critical radius18.750mm
Critical outer diameter37.500mm
Heat loss per metre, bare6.0319W/m
Heat loss per metre, insulated9.8737W/m
Insulated loss as a share of bare163.69%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 mm cable, PVC k 0.2, h 10, 5 mm insulation (below r_c). The inputs, in the units selected above:

InputValue
Insulation thermal conductivity0.20000 W/(m·K)
Outside surface heat transfer coefficient10.000 W/(m²·K)
Pipe or wire outer diameter10.000 mm
Insulation thickness5.0000 mm
Pipe surface temperature80.000 °C
Ambient temperature25.000 °C

Applying the formula below gives:

ResultValue
Critical radius20.000 mm
Critical outer diameter40.000 mm
Heat loss per metre, bare17.279 W/m
Heat loss per metre, insulated25.663 W/m
Insulated loss as a share of bare148.53 %

Open this example in the calculator and change any input.

Formula

\(r_c = \frac{k}{h}\)

\(q'_0 = 2\pi r_1 h (T_s - T_a)\)

\(q' = \frac{T_s - T_a}{\frac{\ln(r_2/r_1)}{2\pi k} + \frac{1}{2\pi r_2 h}}\)

Variables

Symbol Meaning SI unit
\(k\) insulation conductivity W/(m·K)
\(h\) outside surface coefficient W/(m²·K)
\(D\) pipe or wire outer diameter m
\(t\) insulation thickness m
\(T_s\) pipe surface temperature K
\(T_a\) ambient temperature K
\(r_1\) pipe radius m
\(r_2\) outer radius of insulation m
\(r_c\) critical radius m
\(D_c\) critical diameter m
\(q'_0\) heat loss per metre, bare W/m
\(q'\) heat loss per metre, insulated W/m
\(q' / q'_0\) insulated loss over bare loss -

Method and standards

Heat loss through a cylindrical insulation layer is a balance of conduction resistance, which grows with thickness, and surface resistance, which shrinks as the outer area grows. The loss is greatest at the critical radius k/h.

Where it is used

  • Checking insulation on small tubes, tracers and cables.
  • Explaining why thin insulation on wires helps cooling.
  • Teaching the conduction–convection trade-off.

Common mistakes

  • Applying it to large pipes where it never matters.
  • Using a different h for bare and insulated without saying so.
  • Ignoring radiation in h for hot surfaces.

Assumptions and limits

  • Same h on bare and insulated surfaces; steady state.

References

  • r_c = k/h (cylinder)

Questions and answers

What is the critical radius of PVC insulation in still air?

k/h = 0.2/10 = 20 mm. A 10 mm cable with 5 mm of PVC loses about 48 % more heat than bare: useful for cooling cables.

Does this matter for steam pipes?

Rarely. With mineral wool (k 0.04) the critical radius is about 4 mm, far smaller than any pipe, so insulation always reduces loss.

Why can insulation increase heat loss?

On a thin pipe it adds outer surface faster than it adds resistance, until the outer radius passes r_c.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.