FireCADCalc

Model Testing: Froude and Reynolds Similarity Scaling

Model speed and the scale ratios of velocity, discharge, time, force and power for Froude or Reynolds similarity, and the prototype force from a model test.

Inputs

Examples: Illustrative 1:25 ship modelSpillway model 1:40, same waterPipe fitting model 1:4, Reynolds

Accepted: 1.0001 to 10,000
Accepted: 0.0001 to 1,000 m/s
Accepted: 0.01 to 100
Accepted: 0 to 1,000,000 kN

Results

Dynamic similarity needs the governing dimensionless group equal in model and prototype. Equal Froude number V/√(gL) (ships, spillways, waves) gives V_r = λ^½, Q_r = λ^2.5, T_r = λ^½ and, with density ratio ρ_r, F_r = ρ_rλ³ and P_r = ρ_rλ^3.5. Equal Reynolds number VL/ν in the same fluid gives V_r = 1/λ, which needs impractically high model speeds, so ship models match Froude number and correct friction separately (ITTC). Forces scale as ρV²L².

Model velocity1.2649m/s
Velocity ratio6.3246
Discharge ratio10,119
Time ratio6.3246
Force ratio64,000
Power ratio404,772
Prototype force224.00kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1:25 ship model. The inputs, in the units selected above:

InputValue
Length scale (prototype / model)25.000 -
Prototype velocity5.0000 m/s
Density ratio (prototype / model fluid)1.0250 -
Similarity lawFroude (gravity, free surface)
Force measured on the model0.012000 kN

Applying the formula below gives:

ResultValue
Model velocity1.0000 m/s
Velocity ratio5.0000
Discharge ratio3,125.0
Time ratio5.0000
Force ratio16,016
Power ratio80,078
Prototype force192.19 kN

Open this example in the calculator and change any input.

Formula

\(\text{Froude: } V_r = \lambda^{1/2}, \; F_r = \rho_r\lambda^3; \quad \text{Reynolds: } V_r = \lambda^{-1}, \; F_r = \rho_r\)

Variables

Symbol Meaning SI unit
\(\lambda\) Length scale (prototype / model) -
\(V_p\) Prototype velocity m/s
\(\rho_p/\rho_m\) Density ratio (prototype / model fluid) -
\(\text{law}\) Similarity law -
\(F_m\) Force measured on the model N
\(V_m\) Model velocity m/s
\(V_p/V_m\) Velocity ratio -
\(Q_p/Q_m\) Discharge ratio -
\(T_p/T_m\) Time ratio -
\(F_p/F_m\) Force ratio -
\(P_p/P_m\) Power ratio -
\(F_p\) Prototype force N

Method and standards

Similitude.

Where it is used

  • Ship, spillway and wind-tunnel model planning.
  • Converting model test results.

Common mistakes

  • Scaling viscous drag by Froude law.
  • Forgetting the density ratio.

Assumptions and limits

  • Geometric similarity; one dominant dimensionless group.

References

  • Dimensional analysis and similitude

Questions and answers

Why can't both Froude and Reynolds numbers match?

In the same fluid that would need the model speed to rise and fall at once; one is matched and the other corrected for.

Why is the density ratio included?

Ship models are tested in fresh water while the prototype sails in seawater.

What do the defaults represent?

An illustrative 1:25 ship model for a 5 m/s prototype, fresh water model and seawater prototype, measuring 12 N.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

White, Fluid Mechanics, 7th ed. (McGraw-Hill, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.