FireCADCalc

Ship Resistance and Effective Power by the ITTC 1957 Friction Line

Frictional, residuary and total resistance and effective power of a ship from length, wetted surface and speed, by the ITTC 1957 line with a form factor.

Inputs

Examples: Illustrative: 120 m cargo ship at 15 kn, k 0.20, CR 0.0006Tanker 240 m at 14 kn, S 15,500 m2Patrol boat 40 m at 25 kn, CR 0.004

Accepted: 1 to 500 m
Accepted: 0 to 50,000 m²
Accepted: 0.5 to 80 m
Accepted: 0.1 to 30 m
Accepted: 0.3 to 0.95
Accepted: 0.19438 to 77.754 kn
Accepted: 0 to 0.6
Accepted: 0 to 0.01
Accepted: -0.001 to 0.002
Accepted: 990 to 1,040 kg/m³
Accepted: 0.5 to 2 mm²/s

Results

C_T = (1 + k)C_F + C_R + C_A with C_F = 0.075/(log₁₀Re − 2)² (ITTC 1957). C_R comes from model tests or a series (Holtrop, Taylor, Series 60). Wetted surface by Mumford, S = L(1.7T + C_B B), when not entered.

Wetted surface used3,210.0m²
Froude number V/√(gL)0.22495
Reynolds number VL/ν7.7815e+08
ITTC 1957 friction coefficient0.001579
Total resistance coefficient0.002895
Total resistance283.63kN
Effective (towing) power R_T V2,188.6kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 120 m cargo ship at 15 kn, k 0.20, CR 0.0006. The inputs, in the units selected above:

InputValue
Waterline length120.00 m
Wetted surface area (0 to estimate by Mumford)0 m²
Breadth (for the estimate)20.000 m
Draught (for the estimate)7.5000 m
Block coefficient (for the estimate)0.70000 -
Ship speed15.000 kn
Form factor (1 + k), enter k0.20000 -
Residuary (wave) resistance coefficient6.0000e-04 -
Correlation allowance4.0000e-04 -
Water density (sea 1,025; fresh 1,000)1,025.0 kg/m³
Kinematic viscosity (sea water 15 °C: 1.19 mm²/s)1.1900 mm²/s

Applying the formula below gives:

ResultValue
Wetted surface used3,210.0 m²
Froude number V/√(gL)0.22495
Reynolds number VL/ν7.7815e+08
ITTC 1957 friction coefficient0.001579
Total resistance coefficient0.002895
Total resistance283.63 kN
Effective (towing) power R_T V2,188.6 kW

Open this example in the calculator and change any input.

Formula

\(C_F = \frac{0.075}{(\log_{10}Re - 2)^2}, \quad C_T = (1 + k)C_F + C_R + C_A, \quad R_T = \tfrac{1}{2}\rho SV^2C_T, \quad P_E = R_TV\)

\(S \approx L(1.7T + C_BB)\)

Variables

Symbol Meaning SI unit
\(L_{WL}\) Waterline length m
\(S\) Wetted surface area (0 to estimate by Mumford) m²
\(B\) Breadth (for the estimate) m
\(T\) Draught (for the estimate) m
\(C_B\) Block coefficient (for the estimate) -
\(V\) Ship speed m/s
\(k\) Form factor (1 + k), enter k -
\(C_R\) Residuary (wave) resistance coefficient -
\(C_A\) Correlation allowance -
\(\rho\) Water density (sea 1,025; fresh 1,000) kg/m³
\(\nu\) Kinematic viscosity (sea water 15 °C: 1.19 mm²/s) m²/s
\(F_n\) Froude number V/√(gL) -
\(Re\) Reynolds number VL/ν -
\(C_F\) ITTC 1957 friction coefficient -
\(C_T\) Total resistance coefficient -
\(R_T\) Total resistance N
\(P_E\) Effective (towing) power R_T V W

Method and standards

Ship resistance by the ITTC friction line.

Where it is used

  • Preliminary powering and engine selection.
  • Hull cleaning and speed-power trade-offs.

Common mistakes

  • Using the model C_R at a different Froude number.
  • Forgetting the correlation allowance.

Assumptions and limits

  • Calm deep water, clean hull, steady speed.

References

  • ITTC 1957 model–ship correlation line with a form factor (ITTC 1978 method)

Questions and answers

Why is frictional resistance so important?

For full, slow ships it is 70–90 % of the total; hull roughness and fouling raise it further, which is why hull cleaning saves fuel.

Where does C_R come from?

From a model test at the same Froude number, or from methodical series and regression methods such as Holtrop–Mennen; wave resistance rises steeply above F_n ≈ 0.25.

What do the defaults represent?

An illustrative 120 m cargo ship (20 m beam, 7.5 m draught, C_B 0.70) at 15 knots in sea water with k = 0.20 and C_R = 0.0006.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Molland, Turnock and Hudson, Ship Resistance and Propulsion (Cambridge University Press, 2011), ch. 4 and 5

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.