Induction Motor Equivalent Circuit from No-Load and Locked-Rotor Tests

Stator and rotor resistances, leakage reactances, magnetising reactance and rotational loss of an induction motor from DC, no-load and locked-rotor test readings.

Inputs

Examples: Illustrative: 415 V 15 kW class B motorLarge 3.3 kV class C motor, locked rotor at 25 % frequency

Accepted: 0.0001 to 100 Ω
Accepted: 10 to 15,000 V
Accepted: 0.01 to 5,000 A
Accepted: 1 to 1,000,000 W
Accepted: 1 to 15,000 V
Accepted: 0.01 to 5,000 A
Accepted: 1 to 1,000,000 W
Accepted: 0.05 to 1

Results

Star-equivalent per-phase values. X_LR is scaled to rated frequency; R₂′ includes the correction ((X₂′ + X_m)/X_m)² for the magnetising branch. Use the results in the equivalent-circuit torque–slip calculator.

Stator leakage reactance2.9900Ω
Rotor leakage reactance referred6.9766Ω
Magnetising reactance102.86Ω
Rotor resistance referred0.49489Ω
Rotational (friction, windage and core) loss8,883.4W
No-load power factor0.087477
Locked-rotor impedance per phase2.5525Ω

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative: 415 V 15 kW class B motor. The inputs, in the units selected above:

InputValue
Stator resistance per phase (from the DC test, star equivalent)0.25000 Ω
No-load line voltage415.00 V
No-load current8.5000 A
No-load input power (three-phase)900.00 W
Locked-rotor line voltage85.000 V
Locked-rotor current28.000 A
Locked-rotor input power (three-phase)1,900.0 W
Locked-rotor test frequency relative to rated1.0000 -
Design class (split of the leakage reactance)Class B (X₁ = 0.4 X_LR)

Applying the formula below gives:

ResultValue
Stator leakage reactance0.62216 Ω
Rotor leakage reactance referred0.93324 Ω
Magnetising reactance27.566 Ω
Rotor resistance referred0.59623 Ω
Rotational (friction, windage and core) loss845.81 W
No-load power factor0.14730
Locked-rotor impedance per phase1.7527 Ω

Open this example in the calculator and change any input.

Formula

\(|Z_{LR}| = \frac{V_{br}/\sqrt 3}{I_{br}}, \quad R_{LR} = \frac{P_{br}}{3I_{br}^2}, \quad X_{LR} = \frac{f_{rated}}{f_{test}}\sqrt{|Z_{LR}|^2 - R_{LR}^2}\)

\(X_m = \frac{V_{nl}/\sqrt 3}{I_{nl}} - X_1, \quad R'_2 = (R_{LR} - R_1)\left(\frac{X'_2 + X_m}{X_m}\right)^2, \quad P_{rot} = P_{nl} - 3I_{nl}^2R_1\)

Variables

Symbol Meaning SI unit
\(R_1\) Stator resistance per phase (from the DC test, star equivalent) Ω
\(V_{nl}\) No-load line voltage V
\(I_{nl}\) No-load current A
\(P_{nl}\) No-load input power (three-phase) W
\(V_{br}\) Locked-rotor line voltage V
\(I_{br}\) Locked-rotor current A
\(P_{br}\) Locked-rotor input power (three-phase) W
\(f_{test}/f_{rated}\) Locked-rotor test frequency relative to rated -
\(\text{class}\) Design class (split of the leakage reactance) -
\(X_1\) Stator leakage reactance Ω
\(X'_2\) Rotor leakage reactance referred Ω
\(X_m\) Magnetising reactance Ω
\(R'_2\) Rotor resistance referred Ω
\(P_{rot}\) Rotational (friction, windage and core) loss W
\(\cos\phi_{nl}\) No-load power factor -
\(|Z_{LR}|\) Locked-rotor impedance per phase Ω

Method and standards

Equivalent-circuit parameters from standard motor tests.

Where it is used

  • Motor modelling for starting, drives and protection studies.
  • Repair-shop testing and acceptance checks.

Common mistakes

  • Using line instead of phase values.
  • Using the DC resistance of a delta winding without converting to star.

Assumptions and limits

  • Balanced three-phase motor, star-equivalent values, linear magnetics.

References

  • No-load
  • locked-rotor and DC tests for the per-phase equivalent circuit

Questions and answers

Why test the locked rotor at reduced frequency?

Under normal running the rotor frequency is only a few hertz; testing at about 25 % of rated frequency gives a rotor resistance closer to the running value in deep-bar and double-cage rotors.

How is the leakage reactance split?

By the empirical NEMA design-class ratios: equal for class A and D and wound rotors, 40/60 for class B and 30/70 for class C.

What do the defaults represent?

An illustrative 415 V, 15 kW class B motor: no-load 8.5 A and 900 W, locked rotor 85 V, 28 A and 1,900 W, stator resistance 0.25 Ω per phase.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chapman, Electric Machinery Fundamentals, 5th ed. (McGraw-Hill, 2012), sec. 6.7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.