FireCADCalc

DC Motor Starting Resistor Steps

Total starting resistance, number of steps and the resistance to cut out at each step for a DC motor starter between chosen maximum and switching currents.

Inputs

Examples: Illustrative 250 V motor, 200-350 ALow-resistance armature, many stepsSmall motor, one step

Accepted: 6 to 3,000 V
Accepted: 0.001 to 50 Ω
Accepted: 1 to 10,000 A
Accepted: 0.5 to 10,000 A

Results

At standstill R_tot = V/I_max. As the motor speeds up the back EMF rises and current falls to I_min; cutting out a section then restores I_max, so each total resistance is k = I_min/I_max times the one before: R₁ = R_tot, R₂ = kR_tot, … until the next value would fall below R_A. The last step shorts what remains and its current peak shows whether a further step is needed. Pick I_min to give a reasonable number of steps (Chapman uses this procedure).

Total circuit resistance at standstill0.71429Ω
Ratio I_min/I_max0.57143
Number of resistor steps2.0000
Resistance cut out at the first step0.30612Ω
Resistance cut out at the last step0.008163Ω
Current peak when the last step is shorted204.08A

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 250 V motor, 200-350 A. The inputs, in the units selected above:

InputValue
Supply voltage250.00 V
Armature circuit resistance0.40000 Ω
Maximum starting current350.00 A
Current at which a step is cut out200.00 A

Applying the formula below gives:

ResultValue
Total circuit resistance at standstill0.71429 Ω
Ratio I_min/I_max0.57143
Number of resistor steps2.0000
Resistance cut out at the first step0.30612 Ω
Resistance cut out at the last step0.008163 Ω
Current peak when the last step is shorted204.08 A

Open this example in the calculator and change any input.

Formula

\(R_{tot} = \frac{V_T}{I_{max}}, \quad R_{j+1} = R_j\frac{I_{min}}{I_{max}}\)

Variables

Symbol Meaning SI unit
\(V_T\) Supply voltage V
\(R_A\) Armature circuit resistance Ω
\(I_{max}\) Maximum starting current A
\(I_{min}\) Current at which a step is cut out A
\(R_{tot}\) Total circuit resistance at standstill Ω
\(k\) Ratio I_min/I_max -
\(n\) Number of resistor steps -
\(\Delta R_1\) Resistance cut out at the first step Ω
\(\Delta R_n\) Resistance cut out at the last step Ω
\(I_{peak,n}\) Current peak when the last step is shorted A

Method and standards

Starter steps.

Where it is used

  • DC motor starter and hoist controller design.
  • Teaching DC motor starting.

Common mistakes

  • Too few steps giving large current peaks.
  • Forgetting the armature resistance is part of the total.

Assumptions and limits

  • Steps cut at the same current; inductance and brush drop neglected.

References

  • Geometric grading of starter resistance

Questions and answers

Why does a DC motor need a starter?

At standstill there is no back EMF, so the armature current would be V/R_A, many times rated.

Why are the steps geometric?

Each step is cut out at the same current and restores the same maximum, giving equal current ratios.

What do the defaults represent?

An illustrative 250 V motor with 0.4 Ω armature circuit, current kept between 200 and 350 A.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chapman, Electric Machinery Fundamentals, 5th ed. (McGraw-Hill, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.