DC Shunt Motor Speed by Field Weakening

Armature current, back EMF and speed of a shunt or separately excited DC motor when its field current is reduced, for a constant-torque load.

Inputs

Examples: Illustrative 250 V shunt motor, 5 to 4 A fieldSmall 110 V motor, half fieldMill drive 600 V

Accepted: 6 to 3,000 V
Accepted: 0.001 to 50 Ω
Accepted: 0.1 to 10,000 A
Accepted: 9.5493 to 9,549.3 rpm
Accepted: 0.01 to 100 A
Accepted: 0.01 to 100 A

Results

E = Kφω and T = KφI_A. With flux proportional to field current (unsaturated) and constant load torque, weakening the field raises the armature current by φ₁/φ₂ and the speed by (E₂/E₁)(φ₁/φ₂). This is the classic way to run above base speed at constant power; too weak a field gives high armature current, poor commutation and, if the field is lost, dangerous overspeed.

Back EMF before106.00V
Armature current after16.000A
Back EMF after102.00V
Speed after3,367.9rpm
Load torque (constant)4.6273N·m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 250 V shunt motor, 5 to 4 A field. The inputs, in the units selected above:

InputValue
Armature voltage250.00 V
Armature circuit resistance0.060000 Ω
Armature current before120.00 A
Speed before1,200.0 rpm
Field current before5.0000 A
Field current after4.0000 A

Applying the formula below gives:

ResultValue
Back EMF before242.80 V
Armature current after150.00 A
Back EMF after241.00 V
Speed after1,488.9 rpm
Load torque (constant)231.86 N·m

Open this example in the calculator and change any input.

Formula

\(E = V_T - I_AR_A, \quad I_{A2} = I_{A1}\frac{\phi_1}{\phi_2}, \quad \frac{n_2}{n_1} = \frac{E_2}{E_1}\frac{\phi_1}{\phi_2}\)

Variables

Symbol Meaning SI unit
\(V_T\) Armature voltage V
\(R_A\) Armature circuit resistance Ω
\(I_{A1}\) Armature current before A
\(n_1\) Speed before rad/s
\(I_{F1}\) Field current before A
\(I_{F2}\) Field current after A
\(E_1\) Back EMF before V
\(I_{A2}\) Armature current after A
\(E_2\) Back EMF after V
\(n_2\) Speed after rad/s
\(T\) Load torque (constant) N·m

Method and standards

Field weakening.

Where it is used

  • DC drive speed range above base speed.
  • Teaching DC machine control.

Common mistakes

  • Ignoring the armature current rise.
  • Assuming linear flux in a saturated machine.

Assumptions and limits

  • Flux proportional to field current; constant load torque; no armature reaction.

References

  • DC machine equations with linear magnetisation

Questions and answers

Why does weakening the field raise speed?

Less flux needs more speed to generate the same back EMF.

Why is losing the field dangerous?

With almost no flux, the motor races to try to build back EMF, and armature current soars.

What do the defaults represent?

An illustrative 250 V shunt motor at 1,200 rpm drawing 120 A, field reduced from 5 A to 4 A, constant-torque load.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Chapman, Electric Machinery Fundamentals, 5th ed. (McGraw-Hill, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.