FireCADCalc

Capacitor Value for a Split-Phase Motor (90° Auxiliary Current)

Capacitance that makes the auxiliary winding current of a single-phase motor lead the main winding current by 90° at standstill, with currents and capacitor voltage.

Inputs

Examples: Illustrative 230 V, 50 Hz motor115 V, 60 Hz motorSmall fan motor

Accepted: 10 to 1,000 V
Accepted: 1 to 1,000 Hz
Accepted: 0.01 to 1,000 Ω
Accepted: 0.01 to 1,000 Ω
Accepted: 0.01 to 1,000 Ω
Accepted: 0.01 to 1,000 Ω

Results

Starting torque of a single-phase motor is proportional to I_mI_a sin α, where α is the angle between the winding currents. The main winding current lags the voltage by arctan(X_m/R_m); the auxiliary current lags by arctan[(X_a − X_C)/R_a]. Making them 90° apart needs (X_a − X_C)/R_a = −R_m/X_m, so X_C = X_a + R_aR_m/X_m. With the currents in quadrature the line current is √(I_m² + I_a²). The capacitor must be rated for V_C, often well above the supply voltage; use an AC electrolytic start capacitor for short duty or a film capacitor for continuous (run) duty.

Capacitor reactance7.4875Ω
Capacitance354.27µF
Main winding current30.475A
Auxiliary winding current13.003A
Voltage across the capacitor97.357V
Line current33.133A

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 230 V, 50 Hz motor. The inputs, in the units selected above:

InputValue
Supply voltage230.00 V
Supply frequency50.000 Hz
Main winding resistance (locked rotor)4.5000 Ω
Main winding reactance (locked rotor)3.7000 Ω
Auxiliary winding resistance9.5000 Ω
Auxiliary winding reactance3.5000 Ω

Applying the formula below gives:

ResultValue
Capacitor reactance15.054 Ω
Capacitance211.44 µF
Main winding current39.480 A
Auxiliary winding current15.376 A
Voltage across the capacitor231.47 V
Line current42.368 A

Open this example in the calculator and change any input.

Formula

\(X_C = X_a + \frac{R_aR_m}{X_m}, \quad C = \frac{1}{2\pi fX_C}\)

Variables

Symbol Meaning SI unit
\(V\) Supply voltage V
\(f\) Supply frequency 1/s
\(R_m\) Main winding resistance (locked rotor) Ω
\(X_m\) Main winding reactance (locked rotor) Ω
\(R_a\) Auxiliary winding resistance Ω
\(X_a\) Auxiliary winding reactance Ω
\(X_C\) Capacitor reactance Ω
\(C\) Capacitance F
\(I_m\) Main winding current A
\(I_a\) Auxiliary winding current A
\(V_C\) Voltage across the capacitor V
\(I_L\) Line current A

Method and standards

Start capacitor.

Where it is used

  • Replacing or redesigning start capacitors.
  • Teaching single-phase motor starting.

Common mistakes

  • Using running (not locked-rotor) impedances.
  • Choosing a capacitor voltage rating equal to the supply.

Assumptions and limits

  • Standstill impedances; sinusoidal supply; magnetic coupling of windings neglected.

References

  • Two-winding single-phase motor at standstill

Questions and answers

Why aim for 90° between the currents?

Starting torque is proportional to the sine of the angle between them, so 90° gives the most torque per ampere.

Why is the capacitor voltage higher than the supply?

The capacitor and the auxiliary winding form a partly resonant series circuit.

What do the defaults represent?

Illustrative locked-rotor impedances of a 230 V, 50 Hz motor: main 4.5 + j3.7 Ω, auxiliary 9.5 + j3.5 Ω.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Veinott and Martin, Fractional and Subfractional Horsepower Electric Motors, 4th ed. (McGraw-Hill, 1986)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.