Worked example
Example: 500 t/h 0.8 % to 12 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Stock in | 500.00 t/h |
| Inlet consistency | 0.80000 % |
| Outlet consistency | 12.000 % |
| Filtrate consistency | 0.030000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Thickened stock | 32.164 t/h |
| Filtrate | 467.84 t/h |
| Fibre in the filtrate | 3.3684 t/d |
| Fibre retention | 96.491 % |
Open this example in the calculator and change any input.
Formula
\(\dot m_{out} = \dot m_{in}\frac{C_{in} - C_f}{C_{out} - C_f}, \quad \dot m_f = \dot m_{in} - \dot m_{out}, \quad \dot m_{f,OD} = \dot m_f C_f, \quad R = \frac{\dot m_{out}C_{out}}{\dot m_{in}C_{in}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{in}\) | Stock in | kg/s |
| \(C_{in}\) | Inlet consistency | - |
| \(C_{out}\) | Outlet consistency | - |
| \(C_f\) | Filtrate consistency | - |
| \(\dot m_{out}\) | Thickened stock | kg/s |
| \(\dot m_f\) | Filtrate | kg/s |
| \(\dot m_{f,OD}\) | Fibre in the filtrate | kg/s |
| \(R\) | Fibre retention | - |
Method and standards
Total and fibre balances.
Where it is used
- Thickener and save-all design.
- Fibre loss audits.
Common mistakes
- Ignoring filtrate fines.
- Using % and fractions together.
Assumptions and limits
- Steady state.
References
- Smook
- Handbook for Pulp & Paper Technologists
- 3rd ed. (Angus Wilde, 2002)
- ch. 9.6 (thickening)
Questions and answers
Why does filtrate consistency matter?
Fibre in the filtrate is lost or must be recovered in a save-all.
What outlet consistencies are reached?
Gravity deckers 4–8 %, disc thickeners and presses 10–30 %.
Is the balance exact?
Yes, from total and fibre balances; the consistencies must be measured together.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.