FireCADCalc

Stock Consistency: Flow, Dilution and Thickening

Stock volume flow from OD production and consistency, and the water to add (or remove) to change consistency, by fibre and water balances (Smook).

Pulp and paper

Inputs

Examples: 500 t/d from 4 % to 1 %Thickening 3 % to 12 %

Results

Stock flow at C₁416.67t/h
Volume flow at C₁115.74L/s
Stock flow at C₂104.17t/h
Water to add (+) or remove (−)-312.50t/h
Volume flow at C₂28.935L/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 500 t/d from 4 % to 1 %. The inputs, in the units selected above:

InputValue
Pulp production (oven-dry)500.00 t/d
Present consistency4.0000 %
Target consistency1.0000 %
Stock density1,000.0 kg/m³

Applying the formula below gives:

ResultValue
Stock flow at C₁520.83 t/h
Volume flow at C₁144.68 L/s
Stock flow at C₂2,083.3 t/h
Water to add (+) or remove (−)1,562.5 t/h
Volume flow at C₂578.70 L/s

Open this example in the calculator and change any input.

Formula

\(\dot m = \frac{\dot m_{OD}}{C}, \quad \Delta\dot m_w = \dot m_{OD}\left(\frac{1}{C_2} - \frac{1}{C_1}\right)\)

Variables

Symbol Meaning SI unit
\(\dot m_{OD}\) Pulp production (oven-dry) kg/s
\(C_1\) Present consistency -
\(C_2\) Target consistency -
\(\rho\) Stock density kg/m³
\(\dot m_1\) Stock flow at C₁ kg/s
\(\dot V_1\) Volume flow at C₁ m³/s
\(\dot m_2\) Stock flow at C₂ kg/s
\(\Delta\dot m_w\) Water to add (+) or remove (−) kg/s
\(\dot V_2\) Volume flow at C₂ m³/s

Method and standards

Fibre balance.

Where it is used

  • Stock preparation and pump sizing.
  • Dilution control.

Common mistakes

  • Using % in place of fractions.
  • Forgetting fillers in consistency.

Assumptions and limits

  • Stock density close to water.

References

  • Smook
  • Handbook for Pulp & Paper Technologists
  • 3rd ed. (Angus Wilde, 2002)
  • ch. 9 (consistency: OD fibre as a share of stock mass)

Questions and answers

What is consistency?

Oven-dry fibre as a percentage of the total stock mass.

How much water does dilution take?

From 4 % to 1 % multiplies the stock flow by four: three parts of water per part of stock.

Why do flows rise so fast at low consistency?

Flow is inversely proportional to consistency: the headbox at 0.5 % carries 200 t of water per t of fibre.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.