Worked example
Example: 900 kW refiner, 300 kW no-load, 500 t/d. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Refiner motor power | 900.00 kW |
| No-load power | 300.00 kW |
| Pulp production (oven-dry) | 500.00 t/d |
| Rotor speed | 1,000.0 rpm |
| Cutting edge length per revolution | 60.000 km |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gross specific energy | 43.200 kWh/t |
| Net specific energy | 28.800 kWh/t |
| Net energy, HP-day per short ton (HPD/ton) | 1.4599 |
| Specific edge load (J/m) | 0.60000 |
Open this example in the calculator and change any input.
Formula
\(E_g = \frac{P}{\dot m_{OD}}, \quad E_n = \frac{P - P_0}{\dot m_{OD}}, \quad SEL = \frac{P - P_0}{N L_s}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Refiner motor power | W |
| \(P_0\) | No-load power | W |
| \(\dot m_{OD}\) | Pulp production (oven-dry) | kg/s |
| \(N\) | Rotor speed | 1/s |
| \(L_s\) | Cutting edge length per revolution | m |
| \(E_g\) | Gross specific energy | J/kg |
| \(E_n\) | Net specific energy | J/kg |
| \(E_{HPD}\) | Net energy, HP-day per short ton (HPD/ton) | HPD/ton |
| \(SEL\) | Specific edge load (J/m) | J/m |
Method and standards
Specific energy and edge load definitions.
Where it is used
- Refiner control and plate selection.
Common mistakes
- Using gross energy to compare refiners.
- Forgetting the bar intersections are per revolution.
Assumptions and limits
- Throughput as OD fibre.
- SEL is in J/m (W·s/m) and E_HPD in HP-day per short ton; both are shown as plain numbers in every unit system.
References
- Smook
- Handbook for Pulp & Paper Technologists
- 3rd ed. (Angus Wilde, 2002)
- ch. 13.2 (refining; specific energy in kWh/t or HP-day/ton) and ch. 5 (groundwood specific energy)
- Specific edge load: net power / (speed × cutting edge length)
Questions and answers
Why subtract no-load power?
No-load power is spent pumping and in friction; only net power works on the fibres.
What is a HP-day per ton?
The older North American unit; 1 HPD/short ton ≈ 19.7 kWh/t.
What SEL suits hardwood?
About 0.4–1 J/m; softwood 1.5–4 J/m.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.