Worked example
Example: 400 t/d mud at 75 %, 6.5 GJ/t. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Lime mud to the kiln (dry CaCO₃) | 400.00 t/d |
| Mud dryness | 75.000 % |
| Kiln heat consumption per tonne CaO | 6.5000 MJ/kg |
| Fuel lower heating value | 40.000 MJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| CaO produced | 224.12 t/d |
| CO₂ from calcination | 175.88 t/d |
| Water evaporated from the mud | 133.33 t/d |
| Calcination heat (theoretical) | 8.2475 MW |
| Fuel | 36.419 t/d |
Open this example in the calculator and change any input.
Formula
\(\dot n = \frac{\dot m_{mud}}{M_{CaCO_3}}, \quad \dot m_{CaO} = \dot n M_{CaO}, \quad \dot m_f = \frac{\dot m_{CaO} q}{LHV}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{mud}\) | Lime mud to the kiln (dry CaCO₃) | kg/s |
| \(d\) | Mud dryness | - |
| \(q\) | Kiln heat consumption per tonne CaO | J/kg |
| \(LHV\) | Fuel lower heating value | J/kg |
| \(\dot m_{CaO}\) | CaO produced | kg/s |
| \(\dot m_{CO_2}\) | CO₂ from calcination | kg/s |
| \(\dot m_w\) | Water evaporated from the mud | kg/s |
| \(Q_c\) | Calcination heat (theoretical) | W |
| \(\dot m_f\) | Fuel | kg/s |
Method and standards
Calcination stoichiometry.
Where it is used
- Kiln fuel budgets.
- CO₂ reporting.
Common mistakes
- Using the theoretical heat for fuel.
- Counting mud water as CaCO₃.
Assumptions and limits
- Pure CaCO₃ mud: inerts, residual sodium and unreacted CaO in real mud are not counted, so CaO and CO₂ are slightly overstated.
- Fuel = CaO × q / LHV; it does not depend on the mud dryness entered, which only sets the water evaporated.
References
- Smook
- Handbook for Pulp & Paper Technologists
- 3rd ed. (Angus Wilde, 2002)
- ch. 10 (lime kiln: CaCO₃ → CaO + CO₂)
- Heat of calcination about 178 kJ/mol CaCO₃ (standard enthalpy of reaction at 25 °C)
Questions and answers
Why is real heat use double the theory?
Water in the mud, hot exit gases, hot lime and shell losses.
Does calcination CO₂ count as fossil?
It is process CO₂ from the carbonate, reported separately from fuel CO₂.
How does mud dryness help?
Each extra percent of dryness cuts kiln fuel noticeably; modern filters reach 75–85 %. In this calculator the fuel follows the heat consumption q you enter, so use a lower q for drier mud; the water evaporated is shown for reference.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.