Worked example
Example: 80 → 170 °C in 90 min, 90 min hold. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Start temperature of the ramp | 80.000 °C |
| Cooking temperature | 170.00 °C |
| Ramp time | 90.000 min |
| Hold time at T_c | 90.000 min |
| Target H-factor | 1,500.0 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Relative rate at cooking temperature | 916.76 |
| H-factor of the ramp | 176.73 |
| H-factor of the hold | 1,375.1 |
| Total H-factor | 1,551.9 |
| Hold time for the target H-factor | 86.605 min |
Open this example in the calculator and change any input.
Formula
\(k(T) = \exp\left(43.181 - \frac{16\,113}{T}\right), \quad H = \int k\,dt \ (t\ \text{in hours})\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_0\) | Start temperature of the ramp | K |
| \(T_c\) | Cooking temperature | K |
| \(t_r\) | Ramp time | s |
| \(t_h\) | Hold time at T_c | s |
| \(H^*\) | Target H-factor | - |
| \(k(T_c)\) | Relative rate at cooking temperature | - |
| \(H_r\) | H-factor of the ramp | - |
| \(H_h\) | H-factor of the hold | - |
| \(H\) | Total H-factor | - |
| \(t_h^*\) | Hold time for the target H-factor | s |
Method and standards
Vroom's H-factor; ramp integrated by Simpson's rule.
Where it is used
- Batch and continuous cooking control.
Common mistakes
- Using °C in the exponent.
- Comparing H-factors across wood species.
Assumptions and limits
- Linear ramp; uniform temperature.
References
- Smook
- Handbook for Pulp & Paper Technologists
- 3rd ed. (Angus Wilde, 2002)
- ch. 7 (H-factor: relative reaction rate 1 at 100 °C, area under the rate–time curve)
- Vroom
- Pulp Paper Mag. Can. 58(3): 228 (1957): ln k = 43.181 − 16 113/T
Questions and answers
What is the H-factor?
The area under the relative-rate curve against time in hours; it combines cooking time and temperature into one number.
How strong is the temperature effect?
The rate more than doubles every 10 °C: at 170 °C one hour is worth about 920 H.
Is the ramp important?
Below about 140 °C little happens; most of the H-factor comes from the hold.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.