FireCADCalc

H-Factor of a Kraft Cook (Ramp and Hold)

H-factor of a kraft cook with a linear temperature ramp and a hold, by Vroom's relative rate (1 at 100 °C), and the hold time for a target H-factor.

Pulp and paper

Inputs

Examples: 80 → 170 °C in 90 min, 90 min holdHardwood 160 °C

Results

Equal H-factors give about equal kappa numbers for the same wood and alkali charge; adjust hold time, not temperature, for small corrections.

Relative rate at cooking temperature396.00
H-factor of the ramp60.848
H-factor of the hold792.00
Total H-factor852.85
Hold time for the target H-factor111.99min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 80 → 170 °C in 90 min, 90 min hold. The inputs, in the units selected above:

InputValue
Start temperature of the ramp80.000 °C
Cooking temperature170.00 °C
Ramp time90.000 min
Hold time at T_c90.000 min
Target H-factor1,500.0 -

Applying the formula below gives:

ResultValue
Relative rate at cooking temperature916.76
H-factor of the ramp176.73
H-factor of the hold1,375.1
Total H-factor1,551.9
Hold time for the target H-factor86.605 min

Open this example in the calculator and change any input.

Formula

\(k(T) = \exp\left(43.181 - \frac{16\,113}{T}\right), \quad H = \int k\,dt \ (t\ \text{in hours})\)

Variables

Symbol Meaning SI unit
\(T_0\) Start temperature of the ramp K
\(T_c\) Cooking temperature K
\(t_r\) Ramp time s
\(t_h\) Hold time at T_c s
\(H^*\) Target H-factor -
\(k(T_c)\) Relative rate at cooking temperature -
\(H_r\) H-factor of the ramp -
\(H_h\) H-factor of the hold -
\(H\) Total H-factor -
\(t_h^*\) Hold time for the target H-factor s

Method and standards

Vroom's H-factor; ramp integrated by Simpson's rule.

Where it is used

  • Batch and continuous cooking control.

Common mistakes

  • Using °C in the exponent.
  • Comparing H-factors across wood species.

Assumptions and limits

  • Linear ramp; uniform temperature.

References

  • Smook
  • Handbook for Pulp & Paper Technologists
  • 3rd ed. (Angus Wilde, 2002)
  • ch. 7 (H-factor: relative reaction rate 1 at 100 °C, area under the rate–time curve)
  • Vroom
  • Pulp Paper Mag. Can. 58(3): 228 (1957): ln k = 43.181 − 16 113/T

Questions and answers

What is the H-factor?

The area under the relative-rate curve against time in hours; it combines cooking time and temperature into one number.

How strong is the temperature effect?

The rate more than doubles every 10 °C: at 170 °C one hour is worth about 920 H.

Is the ramp important?

Below about 140 °C little happens; most of the H-factor comes from the hold.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.