FireCADCalc

First-Pass (Single-Pass) and Overall Retention

Single-pass retention on the forming fabric from headbox and white water consistencies (total and ash), and overall retention of furnish added (Smook ch. 15).

Pulp and paper

Inputs

Examples: Fine paperNewsprint

Results

Low first-pass retention loads the white water loop with fines and filler; retention aids raise it.

First-pass retention (total)60.000%
First-pass ash retention30.000%
Overall retention98.361%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Fine paper. The inputs, in the units selected above:

InputValue
Headbox consistency0.80000 %
White water (tray) consistency0.25000 %
Headbox ash consistency0.16000 %
White water ash consistency0.10000 %
Furnish retained in the sheet800.00 t/d
Furnish added with the stock830.00 t/d

Applying the formula below gives:

ResultValue
First-pass retention (total)68.750 %
First-pass ash retention37.500 %
Overall retention96.386 %

Open this example in the calculator and change any input.

Formula

\(FPR = \frac{C_{hb} - C_{ww}}{C_{hb}}, \quad FPAR = \frac{A_{hb} - A_{ww}}{A_{hb}}, \quad R_o = \frac{m_{sheet}}{m_{add}}\)

Variables

Symbol Meaning SI unit
\(C_{hb}\) Headbox consistency -
\(C_{ww}\) White water (tray) consistency -
\(A_{hb}\) Headbox ash consistency -
\(A_{ww}\) White water ash consistency -
\(m_{sheet}\) Furnish retained in the sheet kg/s
\(m_{add}\) Furnish added with the stock kg/s
\(FPR\) First-pass retention (total) -
\(FPAR\) First-pass ash retention -
\(R_o\) Overall retention -

Method and standards

Smook's retention definitions.

Where it is used

  • Wet-end chemistry control.

Common mistakes

  • Sampling headbox and white water at different times.

Assumptions and limits

  • Simultaneous samples.
  • Retentions that cannot be formed (no headbox ash, no furnish added) are not shown; negative ash retention and overall retention above 100 % are flagged.

References

  • Smook
  • Handbook for Pulp & Paper Technologists
  • 3rd ed. (Angus Wilde, 2002)
  • ch. 15 (retention: % single-pass and % overall retention)

Questions and answers

What is first-pass retention?

The share of the solids in the headbox stock that stays on the wire in one pass.

What values are typical?

60–90 % total; ash retention is lower, often 30–60 %.

Why is overall retention higher?

Solids passing the wire return in white water and are retained later.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.