Worked example
Example: Fine paper. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Headbox consistency | 0.80000 % |
| White water (tray) consistency | 0.25000 % |
| Headbox ash consistency | 0.16000 % |
| White water ash consistency | 0.10000 % |
| Furnish retained in the sheet | 800.00 t/d |
| Furnish added with the stock | 830.00 t/d |
Applying the formula below gives:
| Result | Value |
|---|---|
| First-pass retention (total) | 68.750 % |
| First-pass ash retention | 37.500 % |
| Overall retention | 96.386 % |
Open this example in the calculator and change any input.
Formula
\(FPR = \frac{C_{hb} - C_{ww}}{C_{hb}}, \quad FPAR = \frac{A_{hb} - A_{ww}}{A_{hb}}, \quad R_o = \frac{m_{sheet}}{m_{add}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(C_{hb}\) | Headbox consistency | - |
| \(C_{ww}\) | White water (tray) consistency | - |
| \(A_{hb}\) | Headbox ash consistency | - |
| \(A_{ww}\) | White water ash consistency | - |
| \(m_{sheet}\) | Furnish retained in the sheet | kg/s |
| \(m_{add}\) | Furnish added with the stock | kg/s |
| \(FPR\) | First-pass retention (total) | - |
| \(FPAR\) | First-pass ash retention | - |
| \(R_o\) | Overall retention | - |
Method and standards
Smook's retention definitions.
Where it is used
- Wet-end chemistry control.
Common mistakes
- Sampling headbox and white water at different times.
Assumptions and limits
- Simultaneous samples.
- Retentions that cannot be formed (no headbox ash, no furnish added) are not shown; negative ash retention and overall retention above 100 % are flagged.
References
- Smook
- Handbook for Pulp & Paper Technologists
- 3rd ed. (Angus Wilde, 2002)
- ch. 15 (retention: % single-pass and % overall retention)
Questions and answers
What is first-pass retention?
The share of the solids in the headbox stock that stays on the wire in one pass.
What values are typical?
60–90 % total; ash retention is lower, often 30–60 %.
Why is overall retention higher?
Solids passing the wire return in white water and are retained later.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.