FireCADCalc

Digester Steam to Heat Chips and Liquor

Steam needed to heat chips, chip water and cooking liquor in a digester from charge temperature to cooking temperature by direct or indirect heating (IF97).

Pulp and paperIAPWS-IF97 (water and steam)

Inputs

Examples: Direct steam, 12 barIndirect heating, 10 bar

Results

Direct steaming dilutes the liquor with condensate; indirect heating through a liquor heater keeps it out.

Heat required75.784GJ
Steam37.621t
Steam per OD tonne of wood0.75241kg/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Direct steam, 12 bar. The inputs, in the units selected above:

InputValue
OD wood50,000 kg
Wood specific heat1.3400 kJ/(kg·K)
Liquor and water (incl. chip water)200,000 kg
Liquor specific heat3.9000 kJ/(kg·K)
Charge temperature70.000 °C
Cooking temperature170.00 °C
Steam pressure (absolute)12.000 bar
HeatingDirect steam (condensate stays)
Heat loss share5.0000 %

Applying the formula below gives:

ResultValue
Heat required89.158 GJ
Steam43.190 t
Steam per OD tonne of wood0.86379 kg/kg

Open this example in the calculator and change any input.

Formula

\(Q = \frac{(W c_w + M_l c_l)(T_2 - T_1)}{1 - \varepsilon}, \quad m_s = \frac{Q}{h_g - h_c}\)

Variables

Symbol Meaning SI unit
\(W\) OD wood kg
\(c_w\) Wood specific heat J/(kg·K)
\(M_l\) Liquor and water (incl. chip water) kg
\(c_l\) Liquor specific heat J/(kg·K)
\(T_1\) Charge temperature K
\(T_2\) Cooking temperature K
\(p_s\) Steam pressure (absolute) Pa
\(\text{heating}\) Heating -
\(\varepsilon\) Heat loss share -
\(Q\) Heat required J
\(m_s\) Steam kg
\(m_s/W\) Steam per OD tonne of wood kg/kg
\(h_g\) Enthalpy of saturated steam at p_s (IAPWS-IF97) J/kg
\(h_c\) Condensate enthalpy: liquid at T_2 (direct) or saturated at p_s (indirect) J/kg

Method and standards

Sensible heat balance with IF97 steam enthalpies.

Where it is used

  • Digester steam budgets.
  • Comparing heating methods.

Common mistakes

  • Forgetting chip water.
  • Ignoring condensate dilution.

Assumptions and limits

  • Uniform heating; constant specific heats.
  • Direct steaming: the condensate stays and ends as liquid at the cooking temperature, h_c = h(p_s, T_2) from IAPWS-IF97. Indirect: the condensate leaves saturated at p_s.

References

  • Smook
  • Handbook for Pulp & Paper Technologists
  • 3rd ed. (Angus Wilde, 2002)
  • ch. 7–8 (digester heating, direct and indirect)
  • Steam enthalpies from IAPWS-IF97

Questions and answers

Why does direct steaming use less steam?

The condensate stays in the digester and gives up its heat down to cooking temperature.

What specific heat for wood?

About 1.3–1.4 kJ/(kg·K) for dry wood.

What steam use is typical?

1–2 t of steam per OD tonne of wood for batch cooks without heat recovery.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.