FireCADCalc

Wet Steam Properties from Dryness Fraction

Enthalpy, entropy, specific volume and internal energy of wet steam from its pressure and dryness fraction, or the dryness fraction from a known enthalpy (IAPWS-IF97).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerBoiler attendant and boiler operator examinations

Inputs

Examples: 10 bar g, dryness 0.95 kg/cm² g, dryness 0.9515 bar(a), enthalpy 2 600 kJ/kg given

Results

Wet steam: pressure and temperature are tied together, so the dryness fraction is needed to fix the state.

Saturation temperature158.29°C
Dryness fraction95.000%
Enthalpy h = h_f + x h_fg2,651.2kJ/kg
Entropy s = s_f + x s_fg6.5220kJ/(kg·K)
Specific volume v = v_f + x (v_g − v_f)0.30384m³/kg
Internal energy u = h − p v2,471.4kJ/kg
Enthalpy of saturated water668.13kJ/kg
Latent heat of evaporation2,087.4kJ/kg
Enthalpy of dry saturated steam2,755.5kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 bar g, dryness 0.9. The inputs, in the units selected above:

InputValue
Steam pressure (absolute)11.013 bar
What you know besides the pressureDryness fraction
Dryness fraction (when given)90.000 %
Enthalpy of the wet steam (when given)0 kJ/kg

Applying the formula below gives:

ResultValue
Saturation temperature184.12 °C
Dryness fraction90.000 %
Enthalpy h = h_f + x h_fg2,580.8 kJ/kg
Entropy s = s_f + x s_fg6.1143 kJ/(kg·K)
Specific volume v = v_f + x (v_g − v_f)0.15962 m³/kg
Internal energy u = h − p v2,405.0 kJ/kg
Enthalpy of saturated water781.43 kJ/kg
Latent heat of evaporation1,999.3 kJ/kg
Enthalpy of dry saturated steam2,780.7 kJ/kg

Open this example in the calculator and change any input.

Formula

\(h = h_f + x\, h_{fg}, \quad s = s_f + x\, s_{fg}\)

\(v = v_f + x\,(v_g - v_f), \quad u = h - p\, v\)

\(x = \frac{h - h_f}{h_{fg}}\)

Variables

Symbol Meaning SI unit
\(p\) Steam pressure (absolute) Pa
\(\text{given}\) What you know besides the pressure -
\(x\) Dryness fraction (when given) -
\(h_{given}\) Enthalpy of the wet steam (when given) J/kg
\(T_s\) Saturation temperature K
\(h\) Enthalpy h = h_f + x h_fg J/kg
\(s\) Entropy s = s_f + x s_fg J/(kg·K)
\(v\) Specific volume v = v_f + x (v_g − v_f) m³/kg
\(u\) Internal energy u = h − p v J/kg
\(h_f\) Enthalpy of saturated water J/kg
\(h_{fg}\) Latent heat of evaporation J/kg
\(h_g\) Enthalpy of dry saturated steam J/kg

Method and standards

Saturated water and dry saturated steam properties at the pressure come from IAPWS-IF97; wet steam is the mass-weighted mix of the two phases.

Worked example

Steam at 10 bar g (11.013 bar absolute) has a dryness fraction of 0.9. From the steam tables at 11.013 bar: h_f = 781.4 kJ/kg, h_fg = 1999.3 kJ/kg, v_g = 0.1772 m³/kg.

  • h = 781.4 + 0.9 × 1999.3 = 2580.8 kJ/kg
  • v ≈ x v_g = 0.9 × 0.1772 = 0.1595 m³/kg (0.1596 with the water volume added)
  • Saturation temperature 184.1 °C

Where it is used

  • Boiler attendant and operator examinations: steam table questions.
  • Heat content of wet steam from a boiler or a long main.
  • Checking a calorimeter result.

Common mistakes

  • Using gauge pressure in the steam tables, which are in absolute pressure.
  • Applying the dryness fraction to the whole enthalpy (x h_g) instead of to the latent heat only.
  • Using v = x v_g and forgetting the small water volume at high pressure.

Assumptions and limits

  • Wet steam only (dryness 0 to 1).
  • Equilibrium properties; no superheat.

References

  • IAPWS-IF97 (water and steam)

Questions and answers

What is the enthalpy of steam at 10 bar g with dryness 0.9?

The steam boils at 184.1 °C. h = h_f + x h_fg = 781.4 + 0.9 × 1999.3 = 2580.8 kJ/kg, and the specific volume is 0.160 m³/kg.

What does dryness fraction mean?

The mass of dry steam in each kg of wet steam. Dryness 0.9 means 0.9 kg of steam and 0.1 kg of water droplets.

Can I find the dryness from the enthalpy?

Yes, choose enthalpy as the known value: x = (h − h_f)/h_fg. An enthalpy above that of dry saturated steam means the steam is superheated, not wet, and the page says so instead of giving a dryness.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.