Steam Dryness by Throttling Calorimeter

Dryness fraction of wet steam in a main from a throttling calorimeter's pressure and temperature, by the constant-enthalpy (throttling) principle (IAPWS-IF97).

Process steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerBoiler attendant and boiler operator examinations

Inputs

Examples: Main at 10 bar(a), calorimeter 1.013 bar(a) at 120 °CMain at 18 bar(a), 1.05 bar(a) at 130 °CMain at 7 bar(a), 1.013 bar(a) at 108 °C

Results

Dryness fraction in the main96.989%
Superheat in the calorimeter20.026K
Steam enthalpy (constant through the throttle)2,716.5kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Main at 10 bar(a), calorimeter 1.013 bar(a) at 120 °C. The inputs, in the units selected above:

InputValue
Pressure in the main (absolute)10.000 bar
Pressure in the calorimeter after throttling (absolute)1.0132 bar
Temperature in the calorimeter120.00 °C

Applying the formula below gives:

ResultValue
Dryness fraction in the main96.989 %
Superheat in the calorimeter20.026 K
Steam enthalpy (constant through the throttle)2,716.5 kJ/kg

Open this example in the calculator and change any input.

Formula

\(h = h(p_2, T_2) \qquad x_1 = \frac{h - h_f(p_1)}{h_{fg}(p_1)} \qquad \Delta T_{sh} = T_2 - T_{sat}(p_2)\)

Variables

Symbol Meaning SI unit
\(p_1\) main pressure Pa
\(p_2\) calorimeter pressure Pa
\(T_2\) calorimeter temperature K
\(x_1\) dryness in the main –
\(\Delta T_{sh}\) superheat in the calorimeter K
\(h\) steam enthalpy J/kg
\(h_f, h_{fg}\) saturated liquid enthalpy and latent heat at p₁ (IF97) J/kg

Method and standards

Throttling is isenthalpic; enthalpies from FireCAD's IAPWS-IF97.

Where it is used

  • Steam quality checks at boiler outlet and users.
  • Sterilisers and autoclaves needing dry steam.
  • Training and laboratory tests.

Common mistakes

  • Uninsulated calorimeter (heat loss reads as wetter steam).
  • Sampling from the bottom of the pipe where water collects.
  • Using gauge pressures.

Assumptions and limits

  • Adiabatic throttling; representative sample.
  • A result above 100 % dry means the main steam is superheated; no dryness is shown then.
  • A calorimeter superheat below about 2 K is flagged: the thermometer error then dominates.

References

  • Throttling at constant enthalpy
  • IAPWS R7-97 IF97

Questions and answers

How does a throttling calorimeter measure dryness?

Steam from the main is throttled to near atmospheric pressure, where it becomes superheated; its enthalpy is unchanged, so the measured temperature gives the dryness. Steam at 10 bar(a) reaching 120 °C at 1.013 bar(a) was 97.0 % dry.

What if the calorimeter steam is not superheated?

The steam was too wet (below about 95 %); use a separating calorimeter before the throttle.

Why does dryness matter?

Wet steam carries less heat per kg, erodes valves and makes heat exchangers underperform.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.