FireCADCalc

Steam Volume after Throttling to a Vent or Silencer

Temperature, specific volume and volume flow of steam blown down through a safety valve or vent to near-atmospheric pressure, by isenthalpic throttling with IF97.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerDesuperheater and PRDS

Inputs

Examples: Ganapathy: 60,000 lb/h at 650 psia, 800 °F to 15 psiaSaturated 10 bar to atmosphere

Used only for superheated steam; it must be above the saturation temperature at the upstream pressure.

Results

Size silencers and vent pipes on this volume; the velocity in the vent outlet should stay well below sonic.

Kinetic energy is taken as recovered: where the outlet velocity is high, the static temperature and the volume at the outlet differ from these values.

Enthalpy (constant)3,269.5kJ/kg
Temperature after throttling395.64°C
Specific volume after throttling2.9804m³/kg
Volume flow after throttling81,114m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: 60,000 lb/h at 650 psia, 800 °F to 15 psia. The inputs, in the units selected above:

InputValue
Steam flow27,216 kg/h
Upstream pressure (absolute)44.816 bar
Upstream steam conditionSuperheated at the temperature below
Upstream temperature (superheated only)426.67 °C
Pressure after throttling (absolute)1.0342 bar

Applying the formula below gives:

ResultValue
Enthalpy (constant)3,269.5 kJ/kg
Temperature after throttling395.64 °C
Specific volume after throttling2.9804 m³/kg
Volume flow after throttling81,114 m³/h

Open this example in the calculator and change any input.

Formula

\(h_2(p_2, T_2) = h_1(p_1, T_1), \quad \dot V_2 = \dot m\, v_2(p_2, h_1)\)

Variables

Symbol Meaning SI unit
\(\dot m\) Steam flow kg/s
\(p_1\) Upstream pressure (absolute) Pa
\(\text{state}\) Upstream steam condition: dry saturated, or superheated at \(T_1\) –
\(T_1\) Upstream temperature (superheated only; above the saturation temperature at \(p_1\)) K
\(p_2\) Pressure after throttling (absolute) Pa
\(h\) Enthalpy (constant) J/kg
\(T_2\) Temperature after throttling K
\(v_2\) Specific volume after throttling m³/kg
\(\dot V_2\) Volume flow after throttling m³/s

Method and standards

Isenthalpic throttling with IF97.

Where it is used

  • Vent silencer and blow-off pipe sizing.
  • Start-up vent design.

Common mistakes

  • Using the inlet specific volume.
  • Assuming saturated steam at the outlet.

Assumptions and limits

  • Adiabatic valve; kinetic energy recovered. At high outlet velocity the static temperature is lower and the volume different; keep the vent velocity well below sonic for the results to hold.
  • Temperatures follow the unit system (°F in US units, as in Ganapathy's example).
  • The upstream steam is dry saturated or superheated; a temperature at or below the saturation temperature is rejected (it would be water, not steam).

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q1.16 (steam volume after throttling)
  • IAPWS-IF97 (isenthalpic throttling)

Questions and answers

Why is throttling isenthalpic?

No work or heat crosses the valve, and kinetic energy is recovered downstream, so enthalpy stays constant.

Why does superheated steam stay superheated?

Expanding to low pressure at constant enthalpy moves the state further into the superheat region.

What does Ganapathy's example give?

60,000 lb/h at 650 psia, 800 °F throttled to 15 psia: 745 °F and 48 ft³/lb, 2.88 million ft³/h.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.