Worked example
Example: 10 kg/cm² g dry saturated from 60 °C feed, 10 t/h, 80 %, 4 000 kcal/kg. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Boiler pressure (absolute) | 9.8066 bar g |
| Feedwater temperature | 60.000 °C |
| Steam produced | Dry saturated |
| Dryness fraction (wet steam) | 95.000 % |
| Steam temperature (superheated) | 250.00 °C |
| Steam generated | 10,000 kg/h |
| Boiler efficiency | 80.000 % |
| Calorific value of the fuel (same basis, GCV or NCV, as the efficiency) | 16,747 kJ/kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Enthalpy of the feedwater | 252.05 kJ/kg |
| Enthalpy of the steam | 2,780.1 kJ/kg |
| Sensible heat, feedwater to boiling (h_f − h_fw) | 525.91 kJ/kg |
| Latent heat added (x h_fg) | 2,002.1 kJ/kg |
| Heat of superheat (h − h_g) | 0 kJ/kg |
| Total heat per kg of steam | 2,528.0 kJ/kg |
| Heat to the steam | 7,022.3 kW |
| Fuel burnt | 1,886.9 kg/h |
| Evaporation ratio (steam per kg of fuel) | 5.2997 kg/kg |
Open this example in the calculator and change any input.
Formula
\(q = h_s - h_{fw} = \underbrace{(h_f - h_{fw})}_{\text{sensible}} + \underbrace{x\,h_{fg}}_{\text{latent}} + \underbrace{(h - h_g)}_{\text{superheat}}\)
\(\dot Q = \dot m_s\, q, \quad \dot m_f = \frac{\dot Q}{\eta_b\, GCV}, \quad ER = \frac{\dot m_s}{\dot m_f} = \frac{\eta_b\, GCV}{q}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Boiler pressure (absolute) | Pa |
| \(T_{fw}\) | Feedwater temperature | K |
| \(\text{state}\) | Steam produced | - |
| \(x\) | Dryness fraction (wet steam) | - |
| \(T_{sup}\) | Steam temperature (superheated) | K |
| \(\dot m_s\) | Steam generated | kg/s |
| \(\eta_b\) | Boiler efficiency | - |
| \(GCV\) | Calorific value of the fuel (same basis as the efficiency) | J/kg |
| \(h_{fw}\) | Enthalpy of the feedwater | J/kg |
| \(h_s\) | Enthalpy of the steam | J/kg |
| \(q_{sens}\) | Sensible heat, feedwater to boiling (h_f − h_fw) | J/kg |
| \(q_{lat}\) | Latent heat added (x h_fg) | J/kg |
| \(q_{sup}\) | Heat of superheat (h − h_g) | J/kg |
| \(q\) | Total heat per kg of steam | J/kg |
| \(\dot Q\) | Heat to the steam | W |
| \(\dot m_f\) | Fuel burnt | kg/s |
| \(ER\) | Evaporation ratio (steam per kg of fuel) | kg/kg |
Method and standards
Enthalpies from IAPWS-IF97: feedwater as compressed water at the boiler pressure, saturation properties and superheated steam at the boiler pressure.
Worked example
A boiler makes 10 t/h of dry saturated steam at 10 kg/cm² g from feedwater at 60 °C. Efficiency 80 %, coal 4000 kcal/kg.
- Feedwater h_fw = 252.0 kJ/kg; h_f = 778.0 kJ/kg; h_g = 2780.1 kJ/kg at 10.81 bar absolute
- Heat per kg = 2780.1 − 252.0 = 2528.0 kJ/kg
- Heat to steam = 10 000/3600 × 2528.0 = 7022 kW
- Coal = 7022 / (0.8 × 16 747) = 0.524 kg/s = 1887 kg/h; evaporation ratio 5.3
Where it is used
- Boiler attendant examinations: heat to raise steam and fuel burnt.
- Estimating fuel for a planned steam demand.
- Explaining where the fuel's heat goes in a boiler.
Common mistakes
- Using gauge pressure in the steam tables.
- Forgetting the feedwater's own heat (using h_s instead of h_s − h_fw).
- Dividing by efficiency twice, or not at all.
Assumptions and limits
- Steady operation; blowdown and losses are inside the efficiency.
- Feedwater must be liquid at the boiler pressure.
- The efficiency and the calorific value must be on the same basis (both gross or both net); mixing them misstates the fuel.
- The evaporation ratio is computed as η GCV / q, so it is shown even when the steam flow is zero.
- A gauge pressure is converted to absolute with the standard atmosphere (101.325 kPa), not the site barometer.
References
- IAPWS-IF97 (water and steam)
Questions and answers
How much heat makes 1 kg of steam at 10 kg/cm² g from 60 °C feedwater?
2528 kJ/kg (604 kcal/kg): 526 kJ/kg to bring the water to boiling and 2002 kJ/kg to evaporate it.
How much coal for 10 t/h?
7.02 MW to the steam; at 80 % efficiency and 4000 kcal/kg, 1887 kg/h of coal: an evaporation ratio of 5.3 kg of steam per kg of coal.
Why is the feedwater enthalpy not just 4.187 × t?
That is close at low pressure. This calculator takes the water at the boiler pressure, which adds a few kJ/kg at high pressure.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.