Condensate Return Fuel and Water Savings

Heat, fuel and water saved by returning hot condensate to the boiler instead of using cold make-up water, per hour and per year.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationPulp and paperFood, dairy and textileIAPWS-IF97 (water and steam)BoilerFlash vessel and condensate

Inputs

Examples: 5 t/h condensate at 90 °C vs make-up at 30 °C, coal 18.6 MJ/kg, 80 %12 t/h at 120 °C (pressurised) vs 25 °C, gas 50 MJ/kg, 90 %

Only sets the liquid enthalpies; it must keep the condensate liquid.

Results

Fuel saved106.33kg/h
Fuel saved per year850.60t
Water saved per year96,192m³
Heat recovered1,329.1kW
Condensate enthalpy503.93kJ/kg
Make-up water enthalpy105.21kJ/kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 5 t/h condensate at 90 °C vs make-up at 30 °C, coal 18.6 MJ/kg, 80 %. The inputs, in the units selected above:

InputValue
Condensate returned5,000.0 kg/h
Condensate temperature at the feed tank90.000 °C
Make-up water temperature30.000 °C
Pressure of the water (absolute)2.0000 bar
Boiler efficiency (on GCV)80.000 %
Gross calorific value of the fuel18,600 kJ/kg
Operating hours per year8,000.0 h
Density of the make-up water saved (for the yearly volume)998.00 kg/m³

Applying the formula below gives:

ResultValue
Fuel saved84.390 kg/h
Fuel saved per year675.12 t
Water saved per year40,080 m³
Heat recovered348.81 kW
Condensate enthalpy377.07 kJ/kg
Make-up water enthalpy125.92 kJ/kg

Open this example in the calculator and change any input.

Formula

\(\dot Q = \dot m_c\,(h_c - h_{mu}) \qquad \dot m_f = \frac{\dot Q}{\eta\;GCV} \qquad m_f = \dot m_f\,t_{op} \qquad V_w = \frac{\dot m_c\,t_{op}}{\rho}\)

Variables

Symbol Meaning SI unit
\(\dot m_c\) condensate returned kg/s
\(T_c\) condensate temperature at the feed tank K
\(T_{mu}\) make-up water temperature K
\(p\) pressure of the water, absolute Pa
\(\eta\) boiler efficiency on GCV –
\(GCV\) gross calorific value of the fuel J/kg
\(t_{op}\) operating hours per year s
\(\rho\) water density kg/m³
\(\dot m_f\) fuel saved kg/s
\(m_f\) fuel saved per year kg
\(V_w\) water saved per year m³
\(\dot Q\) heat recovered W
\(h_c\) condensate enthalpy J/kg
\(h_{mu}\) make-up water enthalpy J/kg

Method and standards

Energy balance on the feed tank: the heat in the returned condensate above the make-up temperature no longer has to come from fuel. Enthalpies of compressed water from FireCAD's IAPWS-IF97.

Where it is used

  • Justifying condensate recovery systems and pumping traps.
  • Water and chemical audits.
  • Steam cost studies in process plants.

Common mistakes

  • Counting only the heat and forgetting water and chemical savings.
  • Assuming condensate returns at steam temperature: it cools in the lines and loses flash steam.
  • Returning contaminated condensate that harms the boiler.

Assumptions and limits

  • Heat losses of the return line and pumping energy are not deducted.
  • The boiler efficiency is taken as unchanged; a hotter feed can slightly lower it when there is no economiser.
  • Treatment and chemical savings are not included.
  • The saving is referred to make-up water entering at \(T_{mu}\) at the same point. If the make-up would otherwise be heated by deaerator steam or blowdown heat recovery, the fuel saved differs.
  • The yearly water volume uses the density you enter for the make-up water (998 kg/m³ at about 20 °C by default), not the density of the hot condensate.

References

  • IAPWS R7-97(2012) IF97 (enthalpies)

Questions and answers

How much fuel does returning condensate save?

Returning 5 t/h at 90 °C in place of make-up at 30 °C brings back 349 kW. At 80 % efficiency on coal of 18.6 MJ/kg that saves 84 kg/h, 675 t a year over 8 000 hours.

Is the water saving counted?

Yes, separately: 40 000 m³ a year in that example, plus the chemicals and treatment the make-up would need.

What about flash steam?

Condensate returned from a higher pressure flashes when it reaches the feed tank. Enter the temperature at the tank, or recover the flash with the flash steam calculator.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.