Single-Phase Natural Circulation Loop Flow

Steady natural circulation flow and temperature rise of a single-phase water loop from heat input, elevation between thermal centres and loop resistance.

Thermal power plant

Inputs

Examples: Illustrative 1 MW loop, 5 m, 7 MPa, 247 CLow-pressure pool loop 50 kW, 2 m, 0.2 MPa, 60 CPWR natural circulation 60 MW, 10 m, 15.5 MPa, 300 C

Accepted: 0.001 to 1,000,000 kW
Accepted: 0.01 to 100 m
Accepted: 0.01 to 100,000 cm²
Accepted: 0.1 to 100,000
Accepted: 0.01 to 30 MPa
Accepted: 6.85 to 366.85 °C

Results

Buoyancy ρβΔT gΔz balances friction ΣK ṁ²/(2ρA²), with ΔT = Q/(ṁc_p): ṁ = [2ρ²A²βgΔzQ/(ΣK c_p)]^(1/3). Boussinesq, point heat source and sink; β by a 1 K central difference of IAPWS-IF97 density.

Natural circulation flow0.73387kg/s
Temperature rise across the heater16.290K
Velocity at the reference area0.14927m/s
Volumetric expansion coefficient523.08µm/(m·K)
Density at the mean temperature983.25kg/m³
Specific heat4.1825kJ/(kg·K)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1 MW loop, 5 m, 7 MPa, 247 C. The inputs, in the units selected above:

InputValue
Heat input1,000.0 kW
Elevation of cooler thermal centre above heater thermal centre5.0000 m
Reference flow area100.00 cm²
Total loss coefficient referred to that area20.000 -
Loop pressure7.0000 MPa
Mean loop temperature246.85 °C

Applying the formula below gives:

ResultValue
Natural circulation flow4.9811 kg/s
Temperature rise across the heater41.892 K
Velocity at the reference area0.61713 m/s
Volumetric expansion coefficient1,854.1 µm/(m·K)
Density at the mean temperature807.13 kg/m³
Specific heat4.7923 kJ/(kg·K)

Open this example in the calculator and change any input.

Formula

\(\dot m = \left(\frac{2\rho^2A^2\beta g\Delta zQ}{c_p\Sigma K}\right)^{1/3}, \quad \Delta T = \frac{Q}{\dot mc_p}\)

Variables

Symbol Meaning SI unit
\(Q\) Heat input W
\(\Delta z\) Elevation of cooler thermal centre above heater thermal centre m
\(A\) Reference flow area m²
\(\Sigma K\) Total loss coefficient referred to that area -
\(p\) Loop pressure Pa
\(\bar T\) Mean loop temperature K
\(\dot m\) Natural circulation flow kg/s
\(\Delta T\) Temperature rise across the heater K
\(v\) Velocity at the reference area m/s
\(\beta\) Volumetric expansion coefficient 1/K
\(\rho\) Density at the mean temperature kg/m³
\(c_p\) Specific heat J/(kg·K)

Method and standards

Natural circulation momentum and energy balance.

Where it is used

  • Decay heat removal and passive safety systems.
  • Solar thermosiphons and transformer cooling loops.

Common mistakes

  • Taking Δz between the vessels instead of between the thermal centres.
  • Mixing loss coefficients referred to different areas.

Assumptions and limits

  • Single phase; steady; Boussinesq; friction as form losses.

References

  • Steady single-phase natural circulation (Boussinesq loop balance)

Questions and answers

Why does flow vary with the cube root of power?

Doubling the heat raises the buoyancy, but friction rises with the square of the flow; together ṁ ∝ Q^(1/3).

How do designers increase natural circulation?

Raise the cooler above the core (larger Δz) and cut the loop resistance; passive plants use tall chimneys.

What do the defaults represent?

An illustrative 1 MW decay-heat loop: 5 m between thermal centres, 0.01 m² reference area, ΣK = 20, water at 7 MPa and 247 °C mean.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 9

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.