Worked example
Example: Illustrative 750 MW SG, 6.9 MPa steam. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steam generator duty | 750.00 MW |
| Primary pressure | 15.500 MPa |
| Primary inlet (hot-leg) temperature | 325.00 °C |
| Primary outlet (cold-leg) temperature | 292.00 °C |
| Steam pressure | 6.9000 MPa |
| Feedwater temperature | 227.00 °C |
| Overall heat transfer coefficient | 6,000.0 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Steam saturation temperature | 284.86 °C |
| Steam flow (dry saturated) | 1,502.7 t/h |
| Primary flow | 14,243 t/h |
| Log-mean temperature difference | 19.115 K |
| Required UA | 39,237 kW/K |
| Heat transfer area | 6,539.5 m² |
Open this example in the calculator and change any input.
Formula
\(\dot m_s = \frac{Q}{h_g(p_s) - h_{fw}}, \quad \Delta T_{lm} = \frac{T_h - T_c}{\ln\frac{T_h - T_{sat}}{T_c - T_{sat}}}, \quad A = \frac{Q}{U\Delta T_{lm}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Steam generator duty | W |
| \(p_p\) | Primary pressure | Pa |
| \(T_h\) | Primary inlet (hot-leg) temperature | K |
| \(T_c\) | Primary outlet (cold-leg) temperature | K |
| \(p_s\) | Steam pressure | Pa |
| \(T_{fw}\) | Feedwater temperature | K |
| \(U\) | Overall heat transfer coefficient | W/(m²·K) |
| \(T_{sat}\) | Steam saturation temperature | K |
| \(\dot m_s\) | Steam flow (dry saturated) | kg/s |
| \(\dot m_p\) | Primary flow | kg/s |
| \(\Delta T_{lm}\) | Log-mean temperature difference | K |
| \(UA\) | Required UA | W/K |
| \(A\) | Heat transfer area | m² |
Method and standards
Steam generator heat balance.
Where it is used
- PWR performance monitoring and fouling trending.
- Teaching and preliminary sizing.
Common mistakes
- Using an LMTD with the feedwater temperature as the cold-side inlet.
- Forgetting tube plugging when comparing area.
Assumptions and limits
- Saturated secondary throughout; dry steam.
References
- Heat balance and LMTD of a recirculating steam generator
Questions and answers
Why is the steam pressure only about 7 MPa?
The secondary must boil below the primary cold-leg temperature (about 290 °C), which limits the saturation pressure; this caps PWR cycle efficiency near 33–35 %.
What U do steam generators achieve?
About 5,000–7,000 W/(m²·K) clean, with thin Inconel tubes and boiling on the outside.
What do the defaults represent?
An illustrative 750 MW steam generator: primary 325 → 292 °C at 15.5 MPa, steam at 6.9 MPa, feedwater 227 °C, U = 6,000 W/(m²·K).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 6