Worked example
Example: Illustrative PWR rod 18 kW/m, 1500 d, 5 % release. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Average linear heat rate | 18.000 kW/m |
| Fuel stack length | 3.6600 m |
| Time at power | 1,500.0 d |
| Stable xenon plus krypton atoms per fission | 0.25000 - |
| Fraction of the gas released to the free volume | 5.0000 % |
| Plenum and gap free volume | 12.000 cm³ |
| Helium fill pressure at 20 °C | 2.0000 MPa |
| Gas temperature in operation | 326.85 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fissions in the rod | 2.6645e+23 |
| Fission gas released (mol) | 0.005531 |
| Helium fill (mol) | 0.009847 |
| Helium pressure hot | 4.0935 MPa |
| Rod internal pressure | 6.3927 MPa |
Open this example in the calculator and change any input.
Formula
\(N_f = \frac{\bar q'Lt}{E_f}, \quad n_{fg} = \frac{yfN_f}{N_A}, \quad p = \frac{(n_{He} + n_{fg})RT_g}{V}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\bar q'\) | Average linear heat rate | W/m |
| \(L\) | Fuel stack length | m |
| \(t\) | Time at power | s |
| \(y\) | Stable xenon plus krypton atoms per fission | - |
| \(f\) | Fraction of the gas released to the free volume | - |
| \(V\) | Plenum and gap free volume | m³ |
| \(p_0\) | Helium fill pressure at 20 °C | Pa |
| \(T_g\) | Gas temperature in operation | K |
| \(N_f\) | Fissions in the rod | - |
| \(n_{fg}\) | Fission gas released (mol) | - |
| \(n_{He}\) | Helium fill (mol) | - |
| \(p_{He}\) | Helium pressure hot | Pa |
| \(p\) | Rod internal pressure | Pa |
Method and standards
Rod gas inventory.
Where it is used
- Fuel design and end-of-life rod pressure checks.
- Teaching fuel behaviour.
Common mistakes
- Using total fission gas instead of the released fraction.
- Forgetting to heat the fill gas to operating temperature.
Assumptions and limits
- Ideal gas; constant free volume and power.
References
- Ideal-gas balance of fission gas release
Questions and answers
Why is fission gas a problem?
Xenon and krypton released from the pellets raise rod pressure and lower the gap conductance, which heats the fuel and releases more gas.
How much gas is released?
A few per cent of the gas made at moderate temperatures, rising steeply above about 1,200–1,400 °C in the pellet centre.
What do the defaults represent?
An illustrative PWR rod at 18 kW/m for 1,500 days, 0.25 gas atoms per fission, 5 % release, 12 cm³ free volume, 2 MPa helium fill and gas at 327 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 8, Lamarsh and Baratta, Introduction to Nuclear Engineering, 3rd ed. (Prentice Hall, 2001)