BWR Channel Exit Quality and Void Fraction (Drift Flux)

Exit equilibrium quality, boiling height fraction and exit void fraction by the homogeneous and Zuber-Findlay drift-flux models for a boiling water reactor channel.

Thermal power plant

Inputs

Examples: Illustrative BWR bundle 5 MW, 16 kg/sLow flow 10 kg/s, 6 MWSubcooled exit: 1 MW, 20 kg/s

Accepted: 0.1 to 20 MPa
Accepted: 6.85 to 366.85 °C
Accepted: 0.001 to 20 MW
Accepted: 36 to 720,000 kg/h
Accepted: 0.1 to 10,000 cm²
Accepted: 1 to 1.5
Accepted: 0 to 2 m/s

Results

Zuber–Findlay: α = x/[C₀(x + (1 − x)ρ_g/ρ_f) + ρ_gV_gj/G]. Equilibrium quality ignores subcooled boiling near the boiling boundary. Water and steam properties from IAPWS-IF97.

Inlet enthalpy1,225.8kJ/kg
Exit enthalpy1,538.3kJ/kg
Exit equilibrium quality17.999%
Fraction of length to the start of bulk boiling (uniform heating)13.310%
Exit void fraction, homogeneous81.636%
Exit void fraction, drift flux70.720%
Exit mixture density (drift flux)242.42kg/m³
Mass flux1,632.7kg/(m²·s)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative BWR bundle 5 MW, 16 kg/s. The inputs, in the units selected above:

InputValue
Channel pressure7.0000 MPa
Inlet temperature (subcooled)278.00 °C
Channel (bundle) power5.0000 MW
Channel flow57,600 kg/h
Channel flow area98.000 cm²
Distribution parameter1.1300 -
Drift velocity0.24000 m/s

Applying the formula below gives:

ResultValue
Inlet enthalpy1,225.8 kJ/kg
Exit enthalpy1,538.3 kJ/kg
Exit equilibrium quality17.999 %
Fraction of length to the start of bulk boiling (uniform heating)13.310 %
Exit void fraction, homogeneous81.636 %
Exit void fraction, drift flux70.720 %
Exit mixture density (drift flux)242.42 kg/m³
Mass flux1,632.7 kg/(m²·s)

Open this example in the calculator and change any input.

Formula

\(x_e = \frac{h_{in} + Q/\dot m - h_f}{h_{fg}}, \quad \alpha = \frac{x}{C_0\left[x + (1 - x)\rho_g/\rho_f\right] + \rho_gV_{gj}/G}\)

Variables

Symbol Meaning SI unit
\(p\) Channel pressure Pa
\(T_{in}\) Inlet temperature (subcooled) K
\(Q\) Channel (bundle) power W
\(\dot m\) Channel flow kg/s
\(A\) Channel flow area m²
\(C_0\) Distribution parameter -
\(V_{gj}\) Drift velocity m/s
\(h_{in}\) Inlet enthalpy J/kg
\(h_{out}\) Exit enthalpy J/kg
\(x_e\) Exit equilibrium quality -
\(z_b/L\) Fraction of length to the start of bulk boiling (uniform heating) -
\(\alpha_h\) Exit void fraction, homogeneous -
\(\alpha\) Exit void fraction, drift flux -
\(\rho_m\) Exit mixture density (drift flux) kg/m³
\(G\) Mass flux kg/(m²·s)

Method and standards

Channel heat balance with drift-flux void fraction.

Where it is used

  • BWR core thermal hydraulics.
  • Boiling channels in boilers and evaporators.

Common mistakes

  • Using equilibrium quality where subcooled boiling is significant.
  • Using the homogeneous model for void reactivity.

Assumptions and limits

  • Steady state; uniform heating for the boiling height.

References

  • Channel energy balance and the Zuber–Findlay drift-flux model

Questions and answers

Why is the drift-flux void lower than homogeneous?

Steam moves faster than the liquid (slip), and gathers in the faster centre of the channel (C₀ > 1), so less volume is occupied by steam than a no-slip model predicts.

Why do voids matter in a BWR?

Steam voids reduce moderation; the void coefficient is negative, so more voids lower the power, and recirculation flow is used to control power.

What do the defaults represent?

An illustrative BWR bundle: 7.0 MPa, inlet 278 °C, 5 MW, 16 kg/s, 98 cm² flow area, C₀ 1.13 and V_gj 0.24 m/s.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Zuber and Findlay, Average volumetric concentration in two-phase flow systems, J. Heat Transfer 87 (1965) 453–468, Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 11

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.