Worked example
Example: Illustrative 1 Ci Co-60 at 2 m behind 5 cm lead, linear buildup. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Source strength (photons per second) | 7.4000e+10 1/s |
| Photon energy | 1.2500 MeV |
| Distance from source to the point of interest | 2.0000 m |
| Shield thickness | 5.0000 cm |
| Linear attenuation coefficient of the shield | 0.66500 1/cm |
| Buildup factor | Linear B = 1 + μx |
| Berger coefficient a | 1.0000 - |
| Berger coefficient b | 0.030000 - |
| Mass energy-absorption coefficient of tissue | 0.029700 cm²/g |
Applying the formula below gives:
| Result | Value |
|---|---|
| Number of mean free paths | 3.3250 |
| Buildup factor | 4.3250 |
| Uncollided flux | 5,295.8 1/(cm²·s) |
| Flux with buildup | 22,904 1/(cm²·s) |
| Absorbed dose rate in tissue | 0.49045 mSv/h |
| Half-value layer | 1.0423 cm |
| Tenth-value layer | 3.4625 cm |
| Transmission B e^(−μx) | 15.558 % |
Open this example in the calculator and change any input.
Formula
\(\phi = \frac{BSe^{-\mu x}}{4\pi r^2}, \quad \dot D = \phi E\frac{\mu_{en}}{\rho}, \quad HVL = \frac{\ln 2}{\mu}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(S\) | Source strength (photons per second) | 1/s |
| \(E\) | Photon energy | J |
| \(r\) | Distance from source to the point of interest | m |
| \(x\) | Shield thickness | m |
| \(\mu\) | Linear attenuation coefficient of the shield | 1/m |
| \(\text{buildup}\) | Buildup factor | - |
| \(a\) | Berger coefficient a | - |
| \(b\) | Berger coefficient b | - |
| \(\mu_{en}/\rho\) | Mass energy-absorption coefficient of tissue | m²/kg |
| \(\mu x\) | Number of mean free paths | - |
| \(B\) | Buildup factor | - |
| \(\phi_0\) | Uncollided flux | 1/(m²·s) |
| \(\phi\) | Flux with buildup | 1/(m²·s) |
| \(\dot D\) | Absorbed dose rate in tissue | Gy/s |
| \(HVL\) | Half-value layer | m |
| \(TVL\) | Tenth-value layer | m |
| \(T\) | Transmission B e^(−μx) | - |
Method and standards
Point-kernel gamma shielding.
Where it is used
- Source storage and radiography bunker design.
- Radiation protection planning.
Common mistakes
- Ignoring buildup for thick shields.
- Using the mass attenuation coefficient without multiplying by density.
Assumptions and limits
- Point isotropic source; slab shield; single energy.
References
- Point-kernel shielding with buildup
Questions and answers
Why is buildup needed?
Photons scattered in the shield still reach the point of interest; ignoring them underestimates the dose behind thick shields by a factor of several.
What is the half-value layer of lead for cobalt-60?
About 1.0–1.2 cm (μ ≈ 0.66 /cm at 1.25 MeV); concrete needs about 6 cm.