Worked example
Example: Illustrative PWR square lattice 12.6 / 9.5 mm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Lattice | Square |
| Rod pitch | 12.600 mm |
| Rod outer diameter | 9.5000 mm |
| Coolant pressure | 15.500 MPa |
| Bulk coolant temperature | 310.00 °C |
| Mass flux | 3,500.0 kg/(m²·s) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pitch-to-diameter ratio | 1.3263 |
| Flow area per rod | 87.878 mm² |
| Hydraulic diameter | 11.778 mm |
| Reynolds number | 487,548 |
| Prandtl number | 0.89819 |
| Weisman bundle factor | 1.3789 |
| Nusselt number | 1,086.8 |
| Heat transfer coefficient | 49,889 W/(m²·K) |
Open this example in the calculator and change any input.
Formula
\(A = P^2 - \frac{\pi D^2}{4}\;\text{or}\;\frac{\sqrt3}{2}P^2 - \frac{\pi D^2}{4}, \quad D_h = \frac{4A}{\pi D}, \quad Nu = \psi\,0.023Re^{0.8}Pr^{0.333}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{lattice}\) | Lattice | - |
| \(P\) | Rod pitch | m |
| \(D\) | Rod outer diameter | m |
| \(p\) | Coolant pressure | Pa |
| \(T\) | Bulk coolant temperature | K |
| \(G\) | Mass flux | kg/(m²·s) |
| \(P/D\) | Pitch-to-diameter ratio | - |
| \(A_{cell}\) | Flow area per rod | m² |
| \(D_h\) | Hydraulic diameter | m |
| \(Re\) | Reynolds number | - |
| \(Pr\) | Prandtl number | - |
| \(\psi\) | Weisman bundle factor | - |
| \(Nu\) | Nusselt number | - |
| \(h\) | Heat transfer coefficient | W/(m²·K) |
Method and standards
Rod-bundle convection.
Where it is used
- Fuel assembly thermal design.
- Heat exchanger rod bundles with longitudinal flow.
Common mistakes
- Using the tube Dittus–Boelter equation for a tight bundle.
- Using the whole assembly area instead of the cell per rod.
Assumptions and limits
- Fully developed turbulent single-phase flow; infinite lattice (no wall subchannels).
References
- Weisman correlation for longitudinal flow in rod bundles
Questions and answers
Why do bundles transfer heat better than tubes?
The open lattice gives more mixing; Weisman's factor ψ is about 1.2–1.4 at typical pitches, so h exceeds the Dittus–Boelter value for the same hydraulic diameter.
What is the flow area per rod in a triangular lattice?
The hexagonal cell around each rod: (√3/2)P² − πD²/4.
What do the defaults represent?
An illustrative PWR lattice: square, 12.6 mm pitch, 9.5 mm rods, 15.5 MPa, 310 °C and 3,500 kg/(m²·s).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Weisman, Heat transfer to water flowing parallel to tube bundles, Nucl. Sci. Eng. 6 (1959) 78–79, Todreas and Kazimi, Nuclear Systems I: Thermal Hydraulic Fundamentals (Hemisphere, 1990), ch. 10